08/26/19
Message Overview:
Fault Message:
[CTK 2] HUDC WRG FAULT
Fault Code:
3430012HUD
Associated CAS:
| Reporting LRU: | Head-Up Flight Display Computer (HFDC) |
| System Description: | 34-32-00 |
| Schematic Diagram: | 34-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-32-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Head-Up Display (HUD) reports a problem.
Possible Causes:
- Head-Up Flight Display Computer (HFDC) (A250)
- Optical Projector Unit (OPU) (A251)
- Head-Up-Display (HUD) Fan (B64)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- 700-34-002 - Modification - Head-Up Display (HUD) System Installation
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrostatic Discharge Safety Precautions | AMM 24-00-00-910-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Head-Up-Display (HUD) System | AMM 34-32-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Head-Up-Display (HUD) Computer | AMM 34-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Head-Up-Display (HUD) Computer | AMM 34-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Head-Up-Display (HUD) Electro-Optical Unit |
AMM 34-32-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Head-Up-Display (HUD) Electro-Optical Unit |
AMM 34-32-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Head-Up-Display (HUD) Computer Tray | AMM 34-32-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Head-Up-Display (HUD) Computer Tray | AMM 34-32-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Flight Deck Effect to Fault Correlations | AMM 45-45-00-970-821 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check if the following fault message is displayed on the CAIMS PMAT.
- If the fault message is not displayed, go to step 3.
- If the fault message is displayed, continue with next step.
- Replace the Head-Up-Display (HUD) Computer. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Perform a continuity check between the Head-Up Flight Display Computer (A250CP1) and the Optical Projection Unit (A251P1) as follows:
From To Result A250CP1-C1/C2 A251P1-z A250CP1-A1/A2 A251P1-A/B A250CP1-G1/G2 A251P1-AA A250CP1-J1/J2 A251P1-LL A250CP1-C7 A251P1-m A250CP1-D7 A251P1-K A250CP1-J4 A251P1-k A250CP1-K4 A251P1-L A250CP1-E4 A251P1-G A250CP1-F4 A251P1-g A250CP1-J5 A251P1-e A250CP1-K5 A251P1-f A250CP1-A7 A251P1-H A250CP1-B7 A251P1-h A250CP1-A5 A251P1-b A250CP1-B5 A251P1-x A250CP1-A4 A251P1-w A250CP1-B4 A251P1-C A250CP1-C5 A251P1-JJ A250CP1-D5 A251P1-F A250CP1-E5 A251P1-D A250CP1-F5 A251P1-HH A250CP1-C4 A251P1-c A250CP1-D4 A251P1-GG A250CP1-G5 A251P1-d A250CP1-H5 A251P1-E A250CP1-J9 A251P1-X A250CP1-K10 A251P1-Z A250CP1-H10 A251P1-U A250CP1-F10 A251P1-Y A250CP1-D10 A251P1-V A250CP1-E10 A251P1-W A250CP1-C9 A251P1-a A250CP1-C10 A251P1-R A250CP1-E9 A251P1-S A250CP1-D9 A251P1-T - If there is no continuity, repair defective wiring as required and do close out.
- If the there is continuity, continue with the next step.
- Check if the following fault message is displayed on the CAIMS PMAT.
- If the fault message is displayed, replace the head-up-display (HUD) electro-optical unit and do close out.
- If the fault message is not displayed, continue with next step.
- Perform the operational test of the head-up-display (HUD) system. Check if the result is satisfactory?
- If the result is satisfactory, do close out.
- If the result is not satisfactory, continue with next step.
- Check if the fault message "COMBINER OPERATIONAL POSITION NOT CORRECT" is displayed on the CAIMS PMAT.
- If the fault message is displayed, check that the head-up-display (HUD) combiner unit is in the operational position and combiner mirror and the optical sensor are in good condition.
- If the fault message is not displayed, continue with the next step.
- Check if the following fault message is displayed on the CAIMS PMAT.
- If the fault message is not displayed, go to step 9.
- If the fault message is displayed, continue with next step.
- Perform a continuity check between the Head-Up Flight Display Computer (A250DP1) and the HUD Tray (B64P1) as follows:
From To Result A250DP1-H5 B64P1-A A250FP1-8 B64P1-B GS1026 B64P1-C - If there is no continuity, repair defective wiring as required and do close out.
- If the there is continuity, replace a head-up-display (HUD) fan and do close out.
- Check if the following fault message is displayed on the CAIMS PMAT.
- If the fault message is displayed, check that the part number between the head-up-display (HUD) computer and head-up-display (HUD) electro-optical unit agree.
- If the fault message is not displayed, continue with the next step.
- Check if the following fault message is displayed on the CAIMS PMAT.
- If the fault message is not displayed, go to step 12.
- If the fault message is displayed, continue with next step.
- Perform a continuity check as follows:
From To Result A250BP1-F4 A250EP1-G5 A250BP1-G4 A250EP1-H5 - If there is no continuity, repair defective wiring as required and do close out.
- If the there is continuity, replace the head-up-display (HUD) computer and do close out.
- Check if the following fault message is displayed on the CAIMS PMAT.
- If the fault message is not displayed, go to step 14.
- If the fault message is displayed, continue with next step.
- Perform a continuity check as follows:
From To Result A250BP1-A4 A250EP1-A1 A250BP1-A5 A250EP1-A2 - If there is no continuity, repair defective wiring as required and do close out.
- If the there is continuity, replace the head-up-display (HUD) computer and do close out.
- Check if the following fault message is displayed on the CAIMS PMAT.
- If the fault messages are not displayed, follow the instructions for the CAIMS - HUDC/WRG FAULT even if the CAIMS - HUDC/WRG FAULT message is not shown on the PMAT.
- If the fault messages are displayed, continue with next step.
- Perform the troubleshooting for the applicable fault message.
- Do close out.