08/28/19
Message Overview:
Fault Message:
SPCB/WRG/HUDC MON FAULT
Fault Code:
343001CHUD
Associated CAS:
| Reporting LRU: | Head-Up Display (HUD) Computer |
| System Description: | 34-32-00 |
| Schematic Diagram: | 34-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-32-05 [ Global Express ] [ G5000 ] [ Global XRS ] 34-32-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Head-Up Display System (HUD) does not receive data from the Stall Protection Computer (SPC).
Possible Causes:
- Head-Up-Display (HUD) Computer (A250)
- Stall Protection Computer (SPC) (A40)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
If more fault reports are sent by a different system about the SPC, do the fault isolation of the stall protection computer.
Quick Links:
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Head-Up-Display (HUD) Computer | AMM 34-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Head-Up-Display (HUD) Computer | AMM 34-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring check between SPC and HUDC as follow:
From To Result A40BP1-35 A250EP1-J4 A40BP1-48 A250EP1-K4 GND A250EP1-J3 A40BP1- SH A250EP1-SH - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
NOTE: When short circuit is detected, remove all interface components and reinstall one at a time to isolate short.
- Replace SPCs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace HUDC.
- Do close out.