08/27/19
Message Overview:
Fault Message:
TCAS/WRG/ COM FAULT
Fault Code:
343001DHUD
Associated CAS:
| Reporting LRU: | Head-Up Display (HUD) System |
| System Description: | 34-32-00 |
| Schematic Diagram: | 34-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-32-04 [ Global Express ] [ G5000 ] [ Global XRS ] 34-43-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Head-Up Display System (HUD) does not receive data from the Traffic/Collision Avoidance System (TCAS).
Possible Causes:
- Head-Up Flight Display (HFDC) (A250)
- Traffic/Collision Avoidance System (TCAS) (A7)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
If more fault reports are sent by a different system about the same radio altimeter, do the Radio Altimeter System - Fault Isolation
Quick Links:
| Removal of the Head-Up-Display (HUD) Computer | AMM 34-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Head-Up-Display (HUD) Computer | AMM 34-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Traffic/Collision Avoidance System (TCAS) Receiver/Transmitter |
AMM 34-43-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Traffic/Collision Avoidance System (TCAS) Receiver/Transmitter |
AMM 34-43-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring check between TCAS, JB4 and HUDC as follows:
From To Result A7EP1-7C A250DP1-K1 A7EP1-7D A250DP1-K2 GND A250DP1-J2 A7EP1- SH A250DP1-SH - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
NOTE: When short circuit is detected, remove all interface components and reinstall one at a time to isolate short.
- Replace TCAS.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace HUDC.