Message Overview:
Fault Message:
IRS 3 TEMP / COOLING FAULT
Fault Code:
3440023IR
Associated CAS:
| Reporting LRU: | Inertial Reference Unit (IRU) 3 |
| System Description: | 34-45-00 |
| Schematic Diagram: | 34-45-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-45-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The internal Inertial Reference Unit (IRU) temperature is higher than the maximum permitted limit (approximately 72°C).
Possible Causes:
- Inertial Reference System (IRS) 3 Cooling Fan
- Inertial Reference System (IRS) 3 Cooling Fan Filter
- Inertial Reference Unit (IRU) 3 (A34)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Inertial Reference System (IRS) Cooling Fans | AMM 21-54-01-000-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Inertial Reference System (IRS) Cooling Fans | AMM 21-54-01-400-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Inertial Reference Units (IRU) | AMM 34-45-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Inertial Reference Units (IRU) | AMM 34-45-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Replace IRU 3 cooling fan.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform a visual inspection of the fan filter for Pull the tab on the filter, remove the filter from the fan and visually inspect the filter.
- If the filter shows sign of degradation, proceed with the replacement of the cooling fan filter and do close out.
- If the filter is dirty, continue with next step.
- Proceed with the cleaning as follows:
- Vacuum the filter using a standard commercial vacuum cleaner or clean the filter using compressed air at a pressure not exceeding 30 psi
- Wash the filter in a mild detergent solution and rinse with water. Temperature of the detergent solution or water shall not exceed 140°F. Chlorine solutions should not be used. Allow the filter to dry and reinstall
- Allow the filter to dry and reinstall
NOTE: If during the cleaning procedure the filter shows signs of degradation, proceed with the replacement of the filter.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace IRU 3.
- Do close out.