09/06/19
Message Overview:
Fault Message:
DAU1/WRG/FWC 37 FAULT (37)
Fault Code:
3440029WX
Associated CAS:
| Reporting LRU: | Weather Radar System |
| System Description: | 34-41-00 |
| Schematic Diagram: | 34-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-42-01 [ Global Express ] [ G5000 ] [ Global XRS ] 34-41-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Weather Radar Transceiver (RTA) does not receiver communication from Data Acquisition Unit (DAU) 1 (GP bus). Amber FAIL legend and fault code 37 display in Multi-Function Display (MFD) status window.
Possible Causes:
- Junction Box 3 (JB3)
- Data Acquisition Unit (DAU) 1 (A17)
- Weather Radar (WXR) Receiver/Transmitter (R/T) (A125)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
The FAIL legend and fault codes show on the MFD status window only when the WXR system is in TST (Test) mode and an active fault has occurred.
Quick Links:
| Removal of the Junction Box JB3 | AMM 24-00-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB3 | AMM 24-00-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Weather Radar Receiver/Transmitter | AMM 34-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Weather Radar Receiver/Transmitter | AMM 34-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform a wiring check for open or short circuit to ground between WX RTA (A125P1), JB3 and DAU 1 (A17CP1).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Swap DAU 1 with DAU 2.
- If system checks are good, replace DAU 1 and do close out.
- If fault remains, continue with next step.
- Replace WXR R/T.
- If system checks are good, do close out.
- If fault remains, continue with next step
- Replace JB3.
- Do close out.