09/05/19
Message Overview:
Fault Message:
INTERFACE - G/S CANCEL DISC FAIL
Fault Code:
3440120AE
Associated CAS:
| Reporting LRU: | Enhanced Ground Proximity Warning System (EGPWS) |
| System Description: | 34-42-00 |
| Schematic Diagram: | 34-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-42-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Glideslope cancel function does not operate properly.
Possible Causes:
- Enhanced Ground Proximity Warning System (EGPWS) Computer (A64)
- Enhanced Ground Proximity Warning System (EGPWS) Control Panel
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter:
- EGPWS Mode 6 Altitude Callout - Navigation-EGPWS-Configuration Strapping for Alternate mode 6 Aural Altitude Callouts
Use EGPWS Level 6 Self-Test to monitor each discrete operation.
Quick Links:
| Removal of the Enhanced Ground-Proximity Warning System (EGPWS) Computer |
AMM 34-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Enhanced Ground-Proximity Warning System (EGPWS) Computer |
AMM 34-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the EGPWS Control Panel | AMM 34-42-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the EGPWS Control Panel | AMM 34-42-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Consult EGPWS - NFF reduction before performing the troubleshooting.
- Perform wiring checks between EGPWS control panel and EGPWS Computer.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace EGPWS control panel.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace EGPWS computer.
- Do close out.