09/06/19
Message Overview:
Fault Message:
FMS 3 PROBE/SENSOR FAULT
Fault Code:
3460008FMS
Associated CAS:
| Reporting LRU: | Flight Management System (FMS) 3 |
| System Description: | 34-60-00 |
| Schematic Diagram: | 34-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-61-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Flight Management System (FMS) does not operate correctly.
Possible Causes:
- Flight Management System Control and Display Unit (FMS CDU) 3 (A218)
- Integrated Avionics Computer (IAC) 3 (A12)
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-34-0348 - Control Display Unit (CDU820) - Intermittent Blanking Display and No Fault Found Update
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Integrated Maintenance Test (IMT) Fault Code Look-Up | AMM 45-45-00-970-826 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the CAIMS PMAT, get access to system diagnostics (AMM TASK 45-45-00-970-804) and perform the CDU-Automatic and Interactive test, and Long Range NAV Sensors-ARINC 429 Bus Status.
- After each test is completed, look for the TEST RESULTS page and record the fault type and code(s) for each IMT fault.
- Perform the IMT fault code look-up procedure (AMM TASK 45-45-00-970-826) to find the applicable troubleshooting procedures.
- Carry out troubleshooting procedures.