09/06/19
Message Overview:
Fault Message:
PASSENGER OXY ON
Fault Code:
PASSOXON
Associated CAS:
| Reporting LRU: | Oxygen System |
| System Description: | 35-20-00 |
| Schematic Diagram: | 35-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 35-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
- Oxygen is supplied to passenger masks manually
- When cabin altitude reaches 14,500 +500 / -700 ft
- Oxygen Test Switch in test
If any above condition is not true, then the following steps apply.
Possible Causes:
- Oxygen Test/reset Switch (S112)
- Oxygen Line Pressure Switch (S52)
- Data Acquisition Unit (DAU) 4 (A31)
- Copilot Bulkhead Relay (K750)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the PASSENGER OXYGEN Control-Panel | AMM 35-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the PASSENGER OXYGEN Control-Panel | AMM 35-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap DAU 4 with DAU 3.
- If system checks are good, replace DAU 4 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between DAU 4, K750, Oxygen line pressure switch and Oxygen test switch.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace Oxygen line pressure switch.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Passenger Oxygen Control
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace K750.
- Do close out.