09/12/19
Message Overview:
Fault Message:
L OUTBD/INBD WAIT SNSR INSTALLATION
Fault Code:
3615419BMC
Associated CAS:
| Reporting LRU: | Bleed Management Controller (BMC) 1 |
| System Description: | 30-12-00 |
| Schematic Diagram: | 30-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-11-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
A Left Wing Leading Edge over-temperature condition is detected by the Outboard Wing Anti-Ice Temperature (WAIT) (Temperature >133°C).
Possible Causes:
- Bleed Management Controller (BMC) 1 (A69)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Anti-Icing Temperature Sensors | AMM 30-11-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Anti-Icing Temperature Sensors | AMM 30-11-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Anti-Ice Temperature Sensors | AIPC 30-11-05 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Verify installation of left OUTBD WAITS as per AMM and re-install if it is out of tolerance.
- If fault disappears, do close out.
- If fault persists, continue with next step.
- Verify installation of left INBD WAITS as per AMM and re-install if it is out of tolerance.
- Do close out.