09/12/19
Message Overview:
Fault Message:
LEFT INBD WING AI TEMP SENSOR /WRG
Fault Code:
3615424BMC
Associated CAS:
| Reporting LRU: | Bleed Management Controller (BMC) 1 |
| System Description: | 30-12-00 |
| Schematic Diagram: | 30-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-11-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
A difference greater than 10°C has been detected between the two temperature sensing elements of the LEFT INBD WING AI TEMP SENSOR. Inhibited during Take-Off and Landing.
NOTE: On BMC P/N GG546-1017-11 and older, the difference is 5°C instead of 10°C.
Possible Causes:
- Left Inboard Wing Anti-Ice Temperature Sensor (E39)
- Bleed Management Controller (BMC) 1 (A69)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-36-0365 - Bleed Management Controller - Data Gathering to reduce No Fault Found (NFF) rate
Forum Articles/Infoservice/Newsletter:
- Forum Article 2011-VOL 8 issue 23 - Bleed Management Controller (BMC) Top 10 No Fault Found (NFF) vs. Reliability Improvement Modification Program (RIMP) implementation
Questionnaire for replacing the BMC. Follow instructions using this (Fill out form).
Quick Links:
| Removal of the Anti-Icing Temperature Sensors | AMM 30-11-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Anti-Icing Temperature Sensors | AMM 30-11-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Management Controller | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Management Controller | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap Left INBD WING AI TEMP SENSOR with Right INBD WING AI TEMP SENSOR.
- If system checks are good, replace Left INBD WING AI TEMP SENSOR and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between BMC 1 and LEFT INBD WING AI TEMP SENSOR.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace BMC 1.
- Do close out.