09/07/19
Message Overview:
Fault Message:
LEFT OUTBD WING AI TEMP SENSOR /WRG
Fault Code:
3615426BMC
Associated CAS:
| Reporting LRU: | Bleed Management Controller (BMC) 1 |
| System Description: | 30-12-00 |
| Schematic Diagram: | 30-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-11-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
A difference of greater than 9°C has been detected between the two Temperature Sensing Elements of the LEFT OUTBD WING AI TEMP SENSOR. Inhibited during Take-off and Landing.
NOTE: On Bleed Management Controller (BMC) P/N GG546-1017-11 and older, the difference is 6°C instead of 9°C.
Possible Causes:
- Left Outboard Anti-Ice Temperature Sensor (E38)
- Bleed Management Controller (BMC) 1 (A69)
- Data Acquisition Unit (DAU) 3 (A30)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-36-0365 - Bleed management controller - Data Gathering to reduce No Fault Found (NFF) rate
Forum Articles/Infoservice/Newsletter:
- Forum Article 2011-VOL 8 issue 23 - Bleed Management Controller (BMC) Top 10 No Fault Found (NFF) vs. Reliability Improvement Modification Program (RIMP) implementation
- Questionnaire for replacing the BMC. Follow instructions using this (Fill out form)
NOTE: The WAIT sensor is a PT500 type which gives 500 ohms at 0°C with resistance increments of approximately 2 ohms per °C.
- The WAITS values can be monitored into CAIMS at any time on the ground. Temperature for Inboard and Outboard sensors should reflect actual ambient temperature
- The value for Inboard sensor is only available for Channel A (Control) in the PMAT. Inboard WAIT from Channel B (Monitoring) can not be obtained
- Resistance of the INBD and OUTBD WAITS sensing elements should be as per the table below in regard to ambient temperature
| Temperature (°C) | Sensor Resistance (Ohms) |
|---|---|
| -60 | 381.64 |
| -50 | 401.505 |
| -40 | 421.317 |
| -30 | 441.074 |
| -20 | 460.774 |
| -10 | 480.417 |
| 500 | |
| 10 | 519.517 |
| 20 | 538.974 |
| 30 | 558.372 |
| 40 | 577.71 |
| 50 | 596.988 |
| 60 | 616.208 |
| 70 | 635.369 |
| 80 | 654.471 |
| 90 | 673.515 |
| 100 | 692.5 |
| 110 | 711.427 |
| 120 | 730.296 |
| 130 | 749.107 |
| 140 | 767.861 |
| 150 | 786.557 |
| 160 | 805.195 |
| 170 | 823.776 |
| 180 | 842.299 |
| 190 | 860.765 |
| 200 | 879.174 |
| 210 | 897.526 |
| 220 | 915.821 |
| 230 | 934.059 |
| 240 | 952.239 |
| 250 | 970.363 |
| 260 | 988.43 |
Quick Links:
| Removal of the Anti-Icing Temperature Sensors | AMM 30-11-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Anti-Icing Temperature Sensors | AMM 30-11-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Management Controller | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Management Controller | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Make sure 'OUTBD WING AI TEMP SENSOR' is installed properly.
- If installation fixes the fault, do close out.
- If fault remains, continue with next step.
- Perform wiring checks between Left Outbd WAITS and BMC 1.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring checks between Left Outbd WAITS and DAU 3.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Swap DAU 3 with DAU 1.
- If system checks are good, replace DAU 3 and do close out.
- If fault remains, continue with next step.
- Swap BMC 1 with BMC 2.
- If system checks are good, replace BMC 1 and do close out.
- If fault remains, continue with next step.
- Replace Left OUTBD WING AI TEMP SENSOR.
- Do close out.