09/13/19
Message Overview:
Fault Message:
CAIMS BATTERY
Fault Code:
4500000CMC
Associated CAS:
| Reporting LRU: | Portable Maintenance Access Terminal (PMAT) Battery |
| System Description: | 45-45-00 |
| Schematic Diagram: | 45-45-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 45-45-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Portable Maintenance Access Terminal (PMAT) has an internal monitor (counter) that counts the number of its power cycles. The PMAT battery can supply power for approximately 800 power cycles during normal operation. This message comes on when the count is at 600 or more. Thus, the PMAT battery must be replaced before it fails.
NOTE: The PMAT 2.0 (P/N 7023300-801) also has a yellow BATT LOW Annunciator light on its Front Panel. This Annunciator light comes on when the Battery power is low.
Possible Causes:
- Portable Maintenance Access Terminal (PMAT) Battery
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Replace the PMAT Battery | AMM 45-45-00-960-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| CAIMS PMAT General Instructions | AMM 45-45-00-970-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| PMAT Shutdown | AMM 45-45-01-840-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Shut down the PMAT.
- Restart the PMAT. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the PMAT battery. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace PMAT.
- Do close out.