Message Overview:
Fault Message:
STARTER MOTOR NOT DISENGAGED
Fault Code:
4960111APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-40-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-12-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The start relay feedback voltage is more than 6 volts after the start relay is commanded off. This shows a possible defective relay in the closed position.
Possible Causes:
- Auxiliary Power Unit (APU) Starter-Contactor Assembly (ASCA) (A48)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the APU Starter-Contactor Assembly | AMM 24-62-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Starter-Contactor Assembly | AMM 24-62-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| APU Safety Precautions | AMM 49-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Engine Branched Wiring-Harness | AMM 49-12-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Engine Branched Wiring-Harness | AMM 49-12-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Examine the engine branched wiring-harness for bare wiring, kinks, worn areas and other damage (WM 49-12).
- If there is bare wiring, kinks, worn areas or other damage, replace engine branched wiring-harness and do close out.
- If NO, continue with next step.
- Check if the STARTER MOTOR NOT DISENGAGED still shows on the CAIMS PMAT.
- If NO, do close out.
- If YES, continue with next step.
- Examine the aircraft wiring harness between the FADEC (A108) and the APU firewall disconnect (STN 1046LHS) (WM 49-61).
- If there is bare wiring, kinks, worn areas or damage, replace or repair defective wiring as required and do close out.
- If NO, continue with next step.
- Check if the STARTER MOTOR NOT DISENGAGED still shows on the CAIMS PMAT.
- If NO, do close out.
- If YES, continue with next step.
- Examine the aircraft wiring harness between the ASCA (A48) and the APU starter motor (B55) (WM 49-61).
- If there is bare wiring, kinks, worn areas or damage, replace or repair defective wiring as required and do close out.
- If NO, continue with next step.
- Check if the STARTER MOTOR NOT DISENGAGED still shows on the CAIMS PMAT.
- If NO, do close out.
- If YES, continue with next step.
- Make sure there is no short between each pin C and the connector shell of A48J2 (connector on ASCA) (WM 49-61).
- If there is a short, go to step 12.
- If there is no short, continue with next step.
- Check if the STARTER MOTOR NOT DISENGAGED still shows on the CAIMS PMAT.
- If NO, do close out.
- If YES, continue with next step.
- Make sure there is no short between each pin C and the connector shell of A48P2 (ASCA interface) (WM 49-61).
- If there is a short, repair or replace defective wiring as required and do close out.
- If there is no short, continue with next step.
- Check if the STARTER MOTOR NOT DISENGAGED still shows on the CAIMS PMAT.
- If NO, do close out.
- If YES, continue with next step.
- Perform wiring checks between A48P2 (ASCA) and A108BP1 (FADEC).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace APU starter-contactor (A48).
- Do close out.