Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

03/28/25

Message Overview:

Message Name:

OP CKT-START MOT DC PWR WRG/SEN WRG

Message Code:

4960112APU

Associated CAS:

None

Reporting LRU: Full Authority Digital Engine Controller (FADEC)
System Description: 49-40-00 - Ignition/Starting
Schematic Diagram: Global Express ]  [ G5000 ]  [ Global XRS ] SSM 49-61-00-101 - APU Automatic Control System
Wiring Diagram: Global Express ]  [ G5000 ]  [ Global XRS ] 49-61-00-01 - Sheet 1 Control - 9002-9129
Global Express ]  [ G5000 ]  [ Global XRS ] 49-61-00-01 - Sheet 2 Fadec Interface - 9002-9129
[ Global Express ]  [ G5000 ]  [ Global XRS ] 49-61-01-1 - Sheet 1 Control - 9159-9249
[ Global Express ]  [ G5000 ]  [ Global XRS ] 49-61-01-1 - Sheet 1 Control - 9250-9431
[ Global Express ]  [ G5000 ]  [ Global XRS ] 49-61-01-1 - Sheet 1 Control - 9127-9129
[ Global Express ]  [ G5000 ]  [ Global XRS ] 49-61-01-1 - Sheet 1 Control - 9130-9249

Message Description:

The start relay feedback voltage is less than 1 volt. This shows a possible open in the signal lines to the Full-Authority Digital Engine-Controller (FADEC).

There is a high resistance between the Auxiliary Power Unit (APU) Full-Authority Digital Engine-Controller (FADEC) and the APU Starter. Experience has shown that (assuming the sense circuit wiring is intact) the problem is Starter Brush wear/sticking.

Possible Causes:

  • Auxiliary Power Unit (APU) Full-Authority Digital Engine-Controller (FADEC) (A108)
  • Auxiliary Power Unit (APU) Starter Motor (B55) (MPE3)
  • Auxiliary Power Unit (APU) Starter Contactor Assembly (ASCA) (A48)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Full Throttle Blog/Forum Articles/Infoservice/Newsletter:

Flight Operation Notifications Manual (FONM): None

Quick Links:

Removal of the APU Starter-Contactor Assembly AMM 24-62-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the APU Starter-Contactor Assembly AMM 24-62-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
APU Safety Precautions AMM 49-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Engine Branched Wiring-Harness AMM 49-12-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Engine Branched Wiring-Harness AMM 49-12-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Starter Motor AMM 49-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Starter Motor AMM 49-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Full-Authority Digital Engine-Controller (FADEC) AMM 49-61-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Full-Authority Digital Engine-Controller (FADEC) AMM 49-61-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Remove the APU FADEC and disconnect the APU Starter motor. Inspect the pins/sockets/lugs for damage, corrosion and/or push back. Perform a continuity check between APU Starter Motor (-) negative and (+) positive terminals (MPE3) as follows:

    From To Result
    A108BP1-H9 MPE3-NEG
    A108BP1-G9 MPE3-POS

    1. If there is continuity, go to step 3.
    2. If there is no continuity, continue with next step.

  2. Perform a continuity check between the APU connector P1 and the engine branched wiring harness as follows:

    From To Result
    APU P1-5 Negative cable
    APU P1-4 Positive cable

    1. If there is no continuity, go to step 5.
    2. If there is continuity, repair defective wiring as required and do close out.

  3. Perform a continuity check between the APU FADEC and relay K2 inside the ASCA as follows:

    From To Result
    A108BP1-C5 A48P2-C

    1. If there is no continuity, go to step 5.
    2. If there is continuity, continue with next step.

  4. Perform continuity check between relay K2 inside the ASCA and the APU Start Motor B55 (MPE3) as follows:

    From To Result
    MPE3-POS A48P2-T5
    MPE3-POS Ground

    1. If there is continuity, go to step 6.
    2. If there is no continuity, continue with next step.

  5. Replace engine branched wiring-harness. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  6. Perform a relay check inside the ASCA (A48) on the APU Start Contactor relay K2.

    1. If relay does not check out, go to step 9.
    2. If relay checks out, continue with next step.

  7. Replace APU Starter Motor.

    1. If APU Start Motor engages, do close out.
    2. If APU Start Motor still does not engage, continue with next step.

  8. Replace APU FADEC.

    1. If starter motor engages, do close out.
    2. If starter motor will not engage, continue with next step.

  9. Replace ASCA.
  10. Do close out.