03/03/21
Message Overview:
Message Name:
EGT SENSOR [CIRCUIT 1 XREF FAILURE]
Message Code:
4960148APU
Associated CAS:
| Reporting LRU: | Auxiliary Power Unit (APU) Full Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-60-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The Auxiliary Power Unit (APU) Full Authority Digital Engine-Controller (FADEC) detected a failure in the Exhaust Gas Temperature (EGT) Sensor Circuit 1. Signal from EGT 1 is 150 °F less than signal from EGT 2 Sensor/Probe. Inhibited during Take-off and Landing.
Possible Causes:
- Exhaust Gas Temperature (EGT) Sensor 1 (TC1-1)
- Auxiliary Power Unit (APU) Full Authority Digital Engine-Controller (FADEC) (A108)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter:
- Honeywell SIL-APU-87 - AIRBORNE AUXILIARY POWER - GAS TURBINE ENGINE-RE220GX APU Auto Shutdown in Heavy Rain
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Removal of the Engine Branched Wiring-Harness | AMM 49-12-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Engine Branched Wiring-Harness | AMM 49-12-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Exhaust Gas Temperature (EGT) Sensor | AMM 49-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Exhaust Gas Temperature (EGT) Sensor | AMM 49-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Gas Turbine Auxiliary | CMM 49-24-35 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Visually inspect the EGT 1 sensor for water, moisture or any damage that could cause a short between the posts.
- Perform continuity check at the EGT 1 sensor receptacle TC1-1 as follows:
From To Expected Result Result TC1-1-A TC1-1-B >20 ohms TC1-1-C TC1-1-D >20 ohms - If there is no continuity, go to step 4.
- If there is continuity, continue with next step.
- Perform wiring checks between sensors EGT 1 (TC1P1) and APU FADEC on connector (A108BP1).
- If wiring checks are not good, repair the defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace EGT 1.
- Do close out.