09/17/19
Message Overview:
Fault Message:
SHORT - FCU/FCU TORQUE MOTOR WRG
Fault Code:
4960179APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-30-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-12-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The signals from the Torque Motor Metering Valve, of the fuel control unit, to the Full-Authority Digital Engine-Controller (FADEC) are not within the expected range. This shows a possible short in the Torque Motor Metering Valve or the engine branched wiring-harness.
Possible Causes:
- Fuel Control Unit (A3)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Engine Branched Wiring-Harness | AMM 49-12-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Engine Branched Wiring-Harness | AMM 49-12-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Fuel Control Unit | AMM 49-30-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Fuel Control Unit | AMM 49-30-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Examine the engine branched wiring-harness for bare wiring, kinks, worn areas and other damage (WM 49-12).
- If the engine branched wiring-harness is not acceptable, replace engine branched wiring-harness and do close out.
- If SHORT - FCU/FCU TORQUE MOTOR WRG still shows on the CAIMS PMAT, continue with next step.
- Examine the fuel control unit (A3) receptacle for contamination and damage.
- If fuel control unit (A3) receptacle is contaminated or damaged, go to step 8.
- If SHORT - FCU/FCU TORQUE MOTOR WRG still shows on the CAIMS PMAT, continue with next step.
- Perform a continuity check between the fuel control unit (A3) receptacle (WM 49-12) as follows:
From To Expected Result Result A3P1-C A3P1-D 30 - 40 ohms - If checks are not good, repair defective wiring as required and do close out.
- If checks are good, continue with next step.
- Make sure there is no short between each A3P1-C and A3P1-D, and the connector shell of A3 receptacle (WM 49-12).
- If short, go to step 8.
- If SHORT - FCU/FCU TORQUE MOTOR WRG still shows on the CAIMS PMAT, continue with next step.
- Make sure there is no short between each P1-41 and P1-42, and the connector shell of P1 (WM 49-12).
- If checks are not good, repair defective wiring as required and do close out.
- If SHORT - FCU/FCU TORQUE MOTOR WRG still shows on the CAIMS PMAT, continue with next step.
- Make sure there is no short between each J802-41 and J802-42, and the connector shell of J802 (WM 49-61).
- If checks are not good, repair defective wiring as required and do close out.
- If checks are good, continue with next step.
- Make sure SHORT - FCU/FCU TORQUE MOTOR WRG does not show on the CAIMS PMAT.
- If checks are not good, repair defective wiring as required and do close out.
- If checks are good, continue with next step.
- Replace Fuel Control Unit.
- Do close out.