Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

09/18/19

Message Overview:

Fault Message:

GROUND SHORT- INLET TEMP SENSOR/WRG

Fault Code:

4960193APU

Associated CAS:

None

Reporting LRU: Full-Authority Digital Engine-Controller (FADEC)
System Description: 49-60-00
Schematic Diagram: 49-61-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 49-12-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
49-61-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Inlet Temperature conditioning voltage in the Full-Authority Digital Engine-Controller (FADEC) is out of range low.

Possible Causes:

  • Auxiliary Power Unit (APU) Full-Authority Digital Engine-Controller (FADEC) (A108)
  • Inlet Temperature Sensor (MT3)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Opening of Non-Thermal Circuit Breakers AMM 24-00-00-863-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of Non-Thermal Circuit Breakers AMM 24-00-00-863-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
APU Safety Precautions AMM 49-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Engine Branched Wiring-Harness AMM 49-12-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Engine Branched Wiring-Harness AMM 49-12-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Full-Authority Digital Engine-Controller (FADEC) AMM 49-61-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Full-Authority Digital Engine-Controller (FADEC) AMM 49-61-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Inlet Temperature Sensor AMM 49-61-09-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Inlet Temperature Sensor AMM 49-61-09-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Open the Auxiliary Power Unit (APU) Access Doors (321BB) AMM 52-43-00-010-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Close the Auxiliary Power Unit (APU) Access Doors (321BB) AMM 52-43-00-410-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Check the engine branched wiring-harness for bare wiring, kinks, worn areas and other damage.

    1. If there is damage, go to step 10.
    2. If there is no damage, continue with next step.

  2. Disconnect the connector MT3P1 from the inlet temperature sensor (MT3). Check the inlet temperature sensor (MT3) receptacle for contamination and damage.

    1. If there is damage, go to step 11.
    2. If there is no damage, continue with next step.

  3. Perform a continuity check within inlet temperature sensor as follows:

    From To Expected Result Result
    MT3P1-A MT3P1-B 50 - 250 ohms

    1. If resistance value is not between 50 to 250 ohms, go to step 11.
    2. If resistance value is between 50 to 250 ohms, continue with next step.

  4. Perform a continuity check between inlet temperature sensor and ground as follows:

    From To Expected Result Result
    MT3P1-A Ground >2 ohms
    MT3P1-B Ground >2 ohms

    1. If resistance value is not more than two ohms, go to step 11.
    2. If resistance value is more than two ohms, continue with next step.

  5. Disconnect the connector P802 at the APU firewall interface (FS1046 LHS). Perform a continuity check between connector P802 and inlet temperature sensor as follows:

    From To Expected Result Result
    P802-63 MT3P1-A <1 ohm
    P802-64 MT3P1-B <1 ohm

    1. If resistance value is more than one ohm for each pair of wires, go to step 10.
    2. If resistance value is less than one ohm for each pair of wires, continue with next step.

  6. Perform a continuity check between connector P802, inlet temperature sensor and ground as follows:

    From To Expected Result Result
    P802-63 Ground Shell >2 ohms
    P802-64 Ground Shell >2 ohms
    MT3P1-A Ground Shell >2 ohms
    MT3P1-B Ground Shell >2 ohms

    1. If resistance value is not more than two ohms for each wire, go to step 10.
    2. If resistance value is more than two ohms for each wire, continue with next step.

  7. Disconnect the connector J802 at the APU firewall interface (FS1046 LHS) and remove the FADEC (A108). Perform a continuity check between connector J802, FADEC and ground as follows:

    From To Expected Result Result
    J802-63 Ground Shell >2 ohms
    J802-64 Ground Shell >2 ohms
    A108BP1-H5 Ground Shell >2 ohms
    A108BP1-J5 Ground Shell >2 ohms

    1. If resistance value is not more than two ohms for each wire, go to step 10.
    2. If resistance value is more than two ohms for each wire, continue with next step.

  8. Perform a continuity check between connector J802 and FADEC as follows:

    From To Expected Result Result
    J802-63 A108BP1-H5 >3 ohms
    J802-64 A108BP1-J5 >3 ohms

    1. If resistance value is not less than three ohms for each wire, repair defective wiring as required and do close out.
    2. If resistance value is less than three ohms for each wire, continue with next step.

  9. Replace the FADEC (A108).

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  10. Replace Engine branched wiring-harness.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  11. Replace Inlet Temperature Sensor (MT3).
  12. Do close out.