Message Overview:
Message Name:
INLET TEMP SENSOR [SIGNAL OUT HIGH]
Message Code:
4960194APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-60-00 - Auxiliary Power Unit |
| Schematic Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-00 - APU Automatic Control System |
| Wiring Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 - APU Automatic Control System 9002-9129 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 - APU Automatic Control System 9130-9158 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-00 - APU Automatic Control System All |
Message Description:
Inlet Temperature signal higher than 199°C (390°F).
Possible Causes:
- Pack Inlet Temperature Sensor 1 (E23)
- Pack Inlet Temperature Sensor 2 (E29)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Standard Aircraft Configuration for Maintenance | [ G5000 ] [ Global Express ] [ Global XRS ] AMM12-00-00-867-801 |
| Connect Electrical Power to the Aircraft | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-861-801 |
| Electrical/Electronic Safety Precautions | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-910-801 |
| Electrostatic Discharge Safety Precautions | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-910-802 |
| Access to Active Faults | [ G5000 ] [ Global Express ] [ Global XRS ] AMM45-45-00-970-802 |
| Access to Stored Faults | [ G5000 ] [ Global Express ] [ Global XRS ] AMM45-45-00-970-803 |
| Access to System Diagnostics | [ G5000 ] [ Global Express ] [ Global XRS ] AMM45-45-00-970-804 |
| Removal of the Engine Branched Wiring-Harness | [ G5000 ] [ Global Express ] [ Global XRS ] AMM49-12-01-000-801 |
| Installation of the Engine Branched Wiring-Harness | [ G5000 ] [ Global Express ] [ Global XRS ] AMM49-12-01-400-801 |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) | [ G5000 ] [ Global Express ] [ Global XRS ] AMM49-61-01-000-801 |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) | [ G5000 ] [ Global Express ] [ Global XRS ] AMM49-61-01-400-801 |
| Removal of the Inlet Temperature Sensor | [ G5000 ] [ Global Express ] [ Global XRS ] AMM49-61-09-000-801 |
| Installation of the Inlet Temperature Sensor | [ G5000 ] [ Global Express ] [ Global XRS ] AMM49-61-09-400-801 |
Troubleshooting Recommendations:
- Visually inspect the engine branched wiring-harness for bare wiring, kinks, worn areas and other damage.
- If harness checks are good, go to step 3.
- If there is bare wiring, kinks, worn areas or other damage, continue with next step.
- Replace or repair Engine branched wiring-harness.
- If fault message is gone, do close out.
- If fault message remains, continue with next step.
- Examine Inlet Temperature Sensor receptacle MT3 for contamination and damage.
- If Inlet Temperature Sensor receptacle MT3 is contaminated or damaged, go to step 7.
- If fault is gone, do close out.
- If fault remains, continue with next step.
- On Inlet Temperature Sensor receptacle MT3, do continuity check between pins A and B. If no open or short are present, continuity should be between 50 and 250 ohms. Continuity at various temperatures are as follows: 32 F = 90.38 ohms, 86 F = 100.91 ohms, 140 F=112.28 ohms and 194 F = 124.55 ohms (refer to CMM).
- If resistance is out of range, go to step 7.
- If resistance is within range and OMS fault remains, continue with next step.
- Perform wiring checks between P802 (APU) and (MT3P1) inlet temperature sensor (T2). Continuity should be less than one ohms, if no open circuit is present (refer to CMM).
- If wiring checks are not good, repair associated wiring and do close out.
- If wiring checks are good, continue with next step.
From To Result P802-63 MT3P1-A (+) P802-64 MT3P1-B (-) - Perform wiring checks between J802 (AC wiring harness) and A108BP1 (APU FADEC).
- If wiring checks are not good, repair associated wiring and do close out.
- If wiring checks are good, continue with step 8.
From To Result J802-63 A108BP1-H5 (+) J802-64 A108BP1-J5 (-) - Replace Inlet Temperature Sensor (T2).
- If fault is gone from the OMS, do close out.
- If fault on the OMS remains, go to step 5.
- Replace APU FADEC.
- Do close out.