09/16/19
Message Overview:
Fault Message:
FADEC [OIL LEVEL SENSOR REF FREQ]
Fault Code:
4960228APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-60-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
Auxiliary Power Unit (APU) Oil Synoptic Display indicates invalid data.
Possible Causes:
- Auxiliary Power Unit (APU) Full Authority Digital Engine Controller (FADEC) (A108)
- Oil Level Sensor (MT2)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None