09/19/19
Message Overview:
Fault Message:
LOAD LEVEL OPEN CKT - APU GCU/WRG
Fault Code:
4960234APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-60-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-22-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Generator load level input conditioning voltage in the Full-Authority Digital Engine-Controller (FADEC) is out of range low. This shows that the Generator load level input or the aircraft wiring harness could have an open.
Possible Causes:
- Full-Authority Digital Engine-Controller (FADEC) (A108)
- Auxiliary Power Unit (APU) Generator Control Unit (GCU) (A109)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Examine the AC wiring harness for bare wiring, kinks, worn areas and other damage.
- If there is bare wiring, kinks, worn areas and other damage, replace AC wiring harness and do close out.
- If there is no damage, continue with next step.
- Perform a wiring check between AC wiring harness connector (P619) and FADEC connector (A108BP1) (WM 24-22).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform a wiring check between AC wiring harness connector (J619) and AC wiring harness connector (P320) (WM 24-22).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform a wiring check between AC wiring harness connector (J320) and APU generator connector (A109P2) (WM 24-22).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform a check of the EICAS primary display to find EICAS messages that are related to the APU generator.
- If there are EICAS primary display to find EICAS messages that are related to the APU generator, troubleshoot the appropriate APU generator fault and do close out.
- If there are no EICAS primary display, continue with next step.
- Replace FADEC.
- Do close out.