Message Overview:
Fault Message:
APU GCU [LOAD LEVEL SIG OUT HIGH]
Fault Code:
4960235APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-60-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-22-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Auxiliary Power Unit (APU) Generator load level input conditioning voltage in the Full-Authority Digital Engine-Controller (FADEC) is out of range high.
Possible Causes:
- Auxiliary Power Unit (APU) Generator Control Unit (GCU) (A109)
- Full-Authority Digital Engine-Controller (FADEC) (A108)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Opening of Non-Thermal Circuit Breakers | AMM 24-00-00-863-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of Non-Thermal Circuit Breakers | AMM 24-00-00-863-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check the AC wiring-harness for bare wiring, kinks, worn areas and other damage.
- If there is damage, repair defective wiring as required and do close out.
- If there is no damage, continue with next step.
- Disconnect the connector P619 at the AFT pressure bulkhead (861 LHS) and remove the FADEC (A108). Perform a continuity check as follows:
From To Result P619-79 A108BP1-G10 P619-80 A108BP1-H10 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Expected Result Result P619-79 Ground > 1 megaohm P619-80 Ground > 1 megaohm A108BP1-G10 Ground > 1 megaohm A108BP1-H10 Ground > 1 megaohm - If resistance value is not more than one megaohm for each wire, repair defective wiring as required and do close out.
- If resistance value is more than one megaohm for each wire, continue with next step.
- Disconnect the P601 connector and perform a continuity check as follows:
From To Expected Result Result P601-A A108BP1-G5 < 1 megaohm - If resistance value is not less than one megaohm for each wire, repair defective wiring as required and do close out.
- If resistance value is less than one megaohm for each wire, continue with next step.
- Perform a continuity check as follows:
From To Expected Result Result P601-A Ground > 1 megaohm A108BP1-G5 Ground > 1 megaohm - If resistance value is not more than one megaohm, repair defective wiring as required and do close out.
- If resistance value is more than one megaohm, continue with next step.
- Disconnect the connector J619 at the AFT pressure bulkhead (861 LHS) and connector P320 (STN 485). Perform a continuity check as follows:
From To Expected Result Result J619-79 P320-118 < 1 megaohm J619-80 P320-117 < 1 megaohm - If resistance value is not less than one megaohm for each wire, repair defective wiring as required and do close out.
- If resistance value is less than one megaohm for each wire, continue with next step.
- Perform a continuity check as follows:
From To Expected Result Result J619-79 Ground > 1 megaohm J619-80 Ground > 1 megaohm P320-118 Ground > 1 megaohm P320-117 Ground > 1 megaohm - If resistance value is not more than one megaohm for each wire, repair defective wiring as required and do close out.
- If resistance value is more than one megaohm for each wire, continue with next step.
- Disconnect J601 connector at the AFT pressure bulkhead (861 LHS) and P325 connector (STN 485). Perform a continuity check as follows:
From To Expected Result Result J601-A P325-11 < 1 ohm - If resistance value is not less than one ohm for each wire, repair defective wiring as required and do close out.
- If resistance value is less than one ohm for each wire, continue with next step.
- Disconnect the connector J320 (STN 485) and connector A109P2 from the APU generator (A109). Perform a continuity check as follows:
From To Expected Result Result J320-118 A109P2-64 < 1 ohm J320-117 A109P2-66 < 1 ohm - If resistance value is not less than one ohm for each wire, repair defective wiring as required and do close out.
- If resistance value is less than one ohm for each wire, continue with next step.
- Perform a continuity check as follows:
From To Expected Result Result J320-118 Ground > 1 megaohm J320-117 Ground > 1 megaohm A109P2-64 Ground > 1 megaohm A109P2-66 Ground > 1 megaohm - If resistance value is not more than one megaohm for each wire, repair defective wiring as required and do close out.
- If resistance value is more than one megaohm for each wire, continue with next step.
- Disconnect the J325 connector (STN 485) and perform a continuity check as follows:
From To Expected Result Result J325-11 A109P2-53 < 1 ohm - If resistance value is not less than one ohm for each wire, repair defective wiring as required and do close out.
- If resistance value is less than one ohm for each wire, continue with next step.
- Perform a continuity check as follows:
From To Expected Result Result J325-11 Ground > 1 megaohm A109P2-53 Ground > 1 megaohm - If resistance value is not more than one megaohm for each wire, repair defective wiring as required and do close out.
- If resistance value is more than one megaohm for each wire, continue with next step.
- Check if EICAS messages that are related to the APU generator are displayed on the EICAS primary display.
- If YES, perform the applicable Troubleshooting for APU generator and do close out.
- If NO, continue with next step.
- Replace FADEC.
- Do close out.