09/20/19
Message Overview:
Fault Message:
GND SHORT - OIL TEMP SENSOR/WIRING
Fault Code:
4960242APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-90-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-12-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Short circuit to ground on the Sensor (+), (-) or (sense) leads.
Possible Causes:
- Oil Temperature Sensor (MT6)
- Auxiliary Power Unit (APU) Full-Authority Digital Engine-Controller (FADEC) (A108)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| APU Safety Precautions | AMM 49-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Engine Branched Wiring-Harness | AMM 49-12-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Engine Branched Wiring-Harness | AMM 49-12-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Oil Temperature Sensor | AMM 49-90-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Oil Temperature Sensor | AMM 49-90-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Open the Auxiliary Power Unit (APU) Access Doors (321BB) |
AMM 52-43-00-010-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Close the Auxiliary Power Unit (APU) Access Doors (321BB) |
AMM 52-43-00-410-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access and disconnect APU Oil temperature sensor connector MT6P1. Perform a complete visual inspection of both mating connectors. Look for contamination or damage.
- If damage or contamination is found, repair/clean as required and do close out.
- If inspection is good, continue with next step
- Perform a continuity check on the sensor as follows:
From To Result MT6J1-A Ground MT6J1-B Ground - If there is continuity, replace the APU Oil Temperature Sensor and do close out.
- If there is no continuity, continue with next step.
- Disconnect APU FADEC connector A108BP1. Perform a continuity check as follows:
From To Result A108BP1-G6 Ground A108BP1-H6 Ground A108BP1-J6 Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Replace the APU FADEC.
- Do close out.