Message Overview:
Fault Message:
SHORT-GEN OIL FLTR DIFFPRESS SW/WRG
Fault Code:
4960249APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-90-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-12-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Before the Auxiliary Power Unit (APU) is started, the Full-Authority Digital Engine-Controller (FADEC) received an indication of a possible clogged Auxiliary Power Unit (APU) Oil-Filter Element. This shows a possible defective Oil-Filter Differential Pressure Switch.
Possible Causes:
- Generator Filter Differential Pressure Switch (S3)
- Auxiliary Power Unit (APU) Full-Authority Digital Engine-Controller (FADEC) (A108)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| APU Safety Precautions | AMM 49-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Engine Branched Wiring-Harness | AMM 49-12-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Engine Branched Wiring-Harness | AMM 49-12-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator-Filter Differential-Pressure Switch | AMM 49-90-35-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator-Filter Differential-Pressure Switch | AMM 49-90-35-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Open the Auxiliary Power Unit (APU) Access Doors (321BB) | AMM 52-43-00-010-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Close the Auxiliary Power Unit (APU) Access Doors (321BB) | AMM 52-43-00-410-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check for the message FADEC CONTROLLER shows on the CAIMS PMAT.
- If message shows, replace FADEC and do close out.
- If message not shows, continue with next step.
- Check for the message SHORT-GEN OIL FLTR DIFFPRESS SW/WRG still shows on the CAIMS PMAT.
- Examine the engine branched wiring-harness for bare wiring, kinks, worn areas and other damage (WM 49-12).
- If there is bare wiring, kinks, worn areas or other damage, go to step 15.
- If not, continue with next step.
- Examine the generator-filter differential-pressure switch (S3) receptacle for contamination and damage.
- If contamination or damage found, go to step 16.
- If not, continue with next step.
- Perform a continuity check within the generator-filter differential-pressure switch (S3) receptacle (WM 49-12). The resistance should measure as follows:
From To Expected Result Result S3P1-A S3P1-B <50 ohms - If measurements are not good, go to step 16.
- If measurements are good, continue with next step.
- Perform a continuity check between generator-filter differential-pressure switch (S3) and the ground shell (WM 49-12). The resistance should measure as follow:
From To Expected Result Result S3P1-A Ground >1 megohm S3P1-B Ground >1 megohm - If measurements are not good, go to step 16.
- If measurements are good, continue with next step.
- Perform wiring check between APU (P1) and generator-filter differential-pressure switch (S3P1).
- If wiring checks are not good, go to step 15.
- If wiring checks are good, continue with next step.
- Perform a continuity check within the generator-filter differential-pressure switch (S3) connector. The resistance should measure as follows:
From To Expected Result Result S3P1-A S3P1-B >50 ohms - If measurements are not good, go to step 15.
- If measurements are good, continue with next step.
- Perform a continuity check between each pin that follows and the ground shell (WM 49-12). The resistance should measure as follows:
From To Expected Result Result P802-49 Ground >1 megohm P802-50 Ground >1 megohm S3P1-A Ground >1 megohm S3P1-B Ground >1 megohm - If measurements are not good, go to step 15.
- If measurements are good, continue with next step.
- Perform wiring checks between aircraft wiring harness (J802) and FADEC (A108AP1).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Check for the message SHORT-GEN OIL FLTR DIFFPRESS SW/WRG still shows on the CAIMS PMAT.
- If message not shows, do close out.
- If message shows, continue with next step.
- Perform a continuity check within the J802 connector (WM 49-61). The resistance should measure as follows:
From To Expected Result Result J802-49 J802-50 >50 ohms - If measurements are not good, repair defective wiring as required and do close out.
- If measurements are good, continue with next step.
- Check for the message SHORT-GEN OIL FLTR DIFFPRESS SW/WRG still shows on the CAIMS PMAT.
- If message not shows, do close out.
- If message shows, continue with next step.
- Perform a continuity check between each pin that follows and the ground shell (WM 49-61). The resistance should measure more than one megohm for each wire.
From To Expected Result Result J802-49 Ground >1 megohm J802-50 Ground >1 megohm A108AP1-J3 Ground >1 megohm A108AP1-H2 Ground >1 megohm - If measurements are good, do close out.
- If measurements are not good, continue with next step.
- Replace engine branched wiring-harness.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Generator Filter Differential Pressure Switch (S3).
- Do close out.