Message Overview:
Fault Message:
LOAD CONT VLV [RVDT POS SIG OUT LO]
Fault Code:
4960280APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-60-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-12-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Full Authority Digital Engine Controller (FADEC) has detected that the Auxiliary Power Unit (APU) Load Control Valve (LCV) is not in the commanded position, by more than 70 degrees.
Possible Causes:
- Load Control Valve (LCV) (MPE1)
- Auxiliary Power Unit (APU) Full-Authority Digital Engine-Controller (FADEC) (A108)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
LCV does not close and position displayed is invalid.
NOTE: The LCV position being read by the FADEC should be the same as shown on the external visual position indicator on the LCV body.
Quick Links:
| Access to Perform LRU/System Operations | AMM 45-47-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Load Control Valve | AMM 49-52-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Load Control Valve | AMM 49-52-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Gas Turbine Auxiliary | CMM 49-24-35 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Re-rack FADEC and verify connector A108AP1.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring checks between APU FADEC connector (A108AP1) and Load Control Valve (LCV) connector (MPE1P1).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace Load Control Valve.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace APU FADEC.
- Do close out.