09/20/19
Message Overview:
Fault Message:
SHORT-START CNTR/TIME TOT METER/WRG
Fault Code:
4960282APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-70-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-12-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Full-Authority Digital Engine-Controller (FADEC) cannot read data from the Time Totalizing Meter or from the Start Counter Meter because the resistance of the load is low. This shows a possible short circuit in the Time Totalizing Meter, Start Counter Meter, the engine branched wiring-harness or the aircraft wiring harness.
Possible Causes:
- Auxiliary Power Unit (APU) Full-Authority Digital Engine-Controller (FADEC) (A108)
- Time Totalizing Meter (M1)
- Start Counter Meter (M2)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| APU Safety Precautions | AMM 49-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Engine Branched Wiring-Harness | AMM 49-12-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Engine Branched Wiring-Harness | AMM 49-12-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Time Totalizing Meter | AMM 49-70-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Time Totalizing Meter | AMM 49-70-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Start Counter Meter | AMM 49-70-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Start Counter Meter | AMM 49-70-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Examine the engine branched wiring-harness for bare wiring, kinks, worn areas and other damage (WM 49-12).
- If there is bare wiring, kinks, worn areas or other damage, replace engine branched wiring-harness and do close out.
- If there is no bare wiring, kinks, worn areas or other damage, coninue with next step.
- If the message SHORT-START CNTR/TIME TOT METER/WRG still shows on the CAIMS PMAT, examine the time totalizing meter (M1) receptacle for contamination and damage.
- If there is contamination or damage, replace the time totalizing meter (M1) and do close out.
- If there is no contamination or damage, continue with next step.
- If the message SHORT-START CNTR/TIME TOT METER/WRG still shows on the CAIMS PMAT, examine the start-counter meter (M2) receptacle for contamination and damage.
- If there is contamination or damage, replace the start counter meter (M2) and do close out.
- If there is no contamination or damage, continue with next step.
- If the message SHORT-START CNTR/TIME TOT METER/WRG still shows on the CAIMS PMAT, connect the hour meter/start counter reader to the time totalizing meter (M1). Push down and hold the push-button on the hour meter/start counter reader.
- If there is no data on the EVENTS LED, replace the time totalizing meter (M1) and do close out.
- If there is data on the EVENTS LED, continue with next step.
- If the message SHORT-START CNTR/TIME TOT METER/WRG still shows on the CAIMS PMAT, perform a check for insulation resistance between the pins of connector M2P1 (WM 49-12). The resistance should measure as follows:
From To Expected Result Result M2P1-A M2P1-B >1 megohm - If the resistance is not as mentioned above, replace engine branched wiring-harness and do close out.
- If the resistance is as mentioned above, continue with next step.
- If the message SHORT-START CNTR/TIME TOT METER/WRG still shows on the CAIMS PMAT, perform a check for insulation resistance between each pin that follows and the ground shell (WM 49-12). The resistance should measure as follows:
From To Expected Result Result P802-67 Ground Shell >1 megohm P802-68 Ground Shell >1 megohm P802-69 Ground Shell >1 megohm M2P1-A Ground Shell >1 megohm M2P1-B Ground Shell >1 megohm M2P1-C Ground Shell >1 megohm - If the resistance is not as mentioned above, replace engine branched wiring-harness and do close out.
- If the resistance is as mentioned above, continue with next step.
- If the message SHORT-START CNTR/TIME TOT METER/WRG still shows on the CAIMS PMAT, perform a check for insulation resistance between the pins of connector M1P1 (WM 49-12). The resistance should measure as follows:
From To Expected Result Result M1P1-A M1P1-B >1 megohm - If the resistance is not as mentioned above, replace engine branched wiring-harness and do close out.
- If the resistance is as mentioned above, continue with next step.
- If the message SHORT-START CNTR/TIME TOT METER/WRG still shows on the CAIMS PMAT, perform a check for insulation resistance between each pin and the ground shell (WM 49-12) as follows:
From To Result P802-59 Ground Shell P802-60 Ground Shell P802-72 Ground Shell M1P1-A Ground Shell M1P1-B Ground Shell M1P1-C Ground Shell - If the checks are not good, replace engine branched wiring-harness and do close out.
- If the checks are good, continue with next step.
- If the message SHORT-START CNTR/TIME TOT METER/WRG still shows on the CAIMS PMAT, perform a check for insulation resistance between the pins of counter meter connector (A108AP1) (WM 49-61). The resistance should measure as follows:
From To Expected Result Result A108AP1-C1 A108AP1-D1 >1 megohm - If the resistance is not as mentioned above, replace engine branched wiring-harness and do close out.
- If the resistance is as mentioned above, continue with next step.
- If the message SHORT-START CNTR/TIME TOT METER/WRG still shows on the CAIMS PMAT, perform a check for insulation resistance between each pin that follows and the ground shell (WM 49-61). The resistance should measure as follows:
From To Expected Result Result J802-67 Ground Shell >1 megohm J802-68 Ground Shell >1 megohm J802-69 Ground Shell >1 megohm A108AP1-C1 Ground Shell >1 megohm A108AP1-D1 Ground Shell >1 megohm A108AP1-C11 Ground Shell >1 megohm - If the resistance is not as mentioned above, replace engine branched wiring-harness and do close out.
- If the resistance is as mentioned above, continue with next step.
- If the message SHORT-START CNTR/TIME TOT METER/WRG still shows on the CAIMS PMAT, perform a check for insulation resistance between the pins of totalizing meter connector (A108AP1) (WM 49-61). The resistance should measure as follows:
From To Expected Result Result A108AP1-B1 A108AP1-A2 >1 megohm - If the resistance is not as mentioned above, replace engine branched wiring-harness and do close out.
- If the resistance is as mentioned above, continue with next step.
- If the message SHORT-START CNTR/TIME TOT METER/WRG still shows on the CAIMS PMAT, perform a check for insulation resistance between each pin that follows and the ground shell (WM 49-61). The resistance should measure as follows:
From To Expected Result Result J802-59 Ground Shell >1 megohm J802-60 Ground Shell >1 megohm J802-72 Ground Shell >1 megohm A108AP1-B1 Ground Shell >1 megohm A108AP1-A2 Ground Shell >1 megohm A108AP1-A1 Ground Shell >1 megohm - If the resistance is not as mentioned above, replace engine branched wiring-harness and do close out.
- If the resistance is as mentioned above, continue with next step.
- Replace FADEC.
- Do close out.