background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/16/21

Message Overview:

Message Name:

FADEC [SURGE VLV SOL DRVR OPEN CKT]

Mesasge Code:

4960302APU

Associated CAS:

None

Reporting LRU: Full-Authority Digital Engine-Controller (FADEC)
System Description: 49-60-00
Schematic Diagram: 49-61-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 49-12-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
49-61-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

No power to the Surge Valve from the Full Authority Digital Engine Controller (FADEC), indicates a possible internal driver open circuit.

Possible Causes:

  • Auxiliary Power Unit (APU) Full-Authority Digital Engine-Controller (FADEC) (A108)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

APU surge in Flight.

Quick Links:

Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Full-Authority Digital Engine-Controller (FADEC) AMM 49-61-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Full-Authority Digital Engine-Controller (FADEC) AMM 49-61-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Stowage of Electrical Wiring - Maintenance Practices - ALL SPM 20-12-05-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Get access to the CAIMS to view other APU related faults.

    1. If fault message is present, troubleshoot them first and continue with next step.
    2. If fault message is not present, continue with next step.

  2. Check for the fault message FADEC CONTROLLER is displayed on the CAIMS.

    1. If the fault message FADEC CONTROLLER is displayed on the CAIMS, go to step 4.
    2. If the fault message FADEC CONTROLLER is not displayed on the CAIMS, continue with next step.

  3. Re-rack APU FADEC and verify condition of connector A108BP1, as well as APU mounting tray connectors for damage.

    1. If damage found, repair as required and do close out.
    2. If damage not found, continue with next step.

  4. Replace APU FADEC.
  5. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.