09/23/19
Message Overview:
Fault Message:
SHORT- INL DR LIN ACTR/CL RELAY WRG
Fault Code:
4960309APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-60-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The signals from the close relay, in the Linear Actuator, to the Full-Authority Digital Engine-Controller (FADEC) are lower than the expected range. This shows a possible short in the Linear Actuator close-relay or the aircraft wiring harness.
Possible Causes:
- Linear Actuator (A199)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Operational Test of the APU Starter-Contactor Assembly |
AMM 24-62-05-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| APU Safety Precautions | AMM 49-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Linear Actuator | AMM 49-14-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Linear Actuator | AMM 49-14-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Examine the linear actuator (A199) receptacle for contamination and damage.
- If there is contamination or damage, go to step 9.
- If there is no contamination or damage, continue with next step.
- If SHORT- INL DR LIN ACTR/CL RELAY WRG still shows on the CAIMS PMAT, perform a continuity check between linear actuator connector (A199P1) receptacle and grounded shell as follows (WM 49-61):
From To Expected Result Result A199P1-A Ground >1 megohm A199P1-D Ground >1 megohm - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- If SHORT- INL DR LIN ACTR/CL RELAY WRG still shows on the CAIMS PMAT, perform a continuity check on aircraft wiring harness connector (P803) as follows (WM 49-61):
From To Expected Result Result P803-L P803-F >1 megohm - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- If SHORT- INL DR LIN ACTR/CL RELAY WRG still shows on the CAIMS PMAT, perform a continuity check between aircraft wiring harness (P803) and grounded shell as follows (WM 49-61):
From To Expected Result Result P803-L Ground > 1megohm P803-F Ground > 1megohm - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- If SHORT- INL DR LIN ACTR/CL RELAY WRG still shows on the CAIMS PMAT, perform a continuity check on aircraft wiring harness connector (P803) as follows (WM 49-61):
From To Expected Result Result P803-L P803-F >1 megohm - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- If SHORT- INL DR LIN ACTR/CL RELAY WRG still shows on the CAIMS PMAT, perform continuity check between aircraft wiring harness connector (J803) and ground shell (WM 49-61) as follows:
From To Expected Result Result J803-L Ground > 1megohm J803-F Ground > 1megohm - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- If SHORT- INL DR LIN ACTR/CL RELAY WRG still shows on the CAIMS PMAT, perform a continuity check between aircraft wiring harness connector (J803) and APU starter-contactor assembly connector (A48P1) as follows (WM 49-61):
From To Expected Result Result J803-L A48P1-e <3 ohms - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- On the APU starter-contactor assembly (A48) receptacle, check if there is 24 volts minimum on A48P1-e.
- If NO, repair defective wiring as required and do close out.
- If YES, continue with next step.
- Replace linear actuator (A199).
- Do close out.