Message Overview:
Fault Message:
POS VS CMD-INLET DOOR LIN ACTR/XDCR
Fault Code:
4960321APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-60-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-12-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Possible Causes:
- Linear Actuator (A199)
- Inlet-Door Rotary Transducer (MT5)
- Full-Authority Digital Engine-Controller (FADEC) (A108)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
APU door position digital readout on the EICAS STATUS PAGE will appear in amber when the door position does not agree with the command from the FADEC.
Quick Links:
| Removal of the Engine Branched Wiring-Harness | AMM 49-12-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Engine Branched Wiring-Harness | AMM 49-12-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Linear Actuator | AMM 49-14-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Linear Actuator | AMM 49-14-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Inlet-Door Rotary Transducer | AMM 49-14-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Inlet-Door Rotary Transducer | AMM 49-14-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Visually check door position and inspect air inlet door for blockage or damage.
- If damages are found, repair as required and do close out.
- If damages are not found, continue with next step.
- Re-rack FADEC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Inspect the linear actuator (A199) and its connector for damage, FOD and contamination,
- If damages are found, repair or replace as required and do close out.
- If damages are not found, continue with next step.
- Inspect the inlet door position rotary transducer and its connector for damage, FOD and contamination.
- If there is a damage, repair or replace as required and do close out.
- If there is no damage, continue with next step.
- Re-rack FADEC and verify condition of connector A108AP1, A108BP1 and A108CP1 as well as APU mounting tray connectors for damage or FOD.
- If damages are found, repair as required and do close out.
- If damages are not found, continue with next step.
- Perform a continuity check between the linear actuator connector (A199P1) and ground shell as follows:
From To Expected Result Result A199P1-A Ground >1 megaohm A199P1-C Ground >1 megaohm - If the resistance check is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance check is as mentioned above, continue with next step.
- Perform wiring checks between and inlet door actuator connector (A199P1) and connector P803.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform a continuity check between the linear actuator connector (A199P1) and ground shell as follows:
From To Expected Result Result A199P1-A Ground >1 megaohm A199P1-B Ground >1 megaohm A199P1-C Ground >1 megaohm A199P1-D Ground >1 megaohm - If the resistance check is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance check is as mentioned above, continue with next step.
- Perform a continuity check between connector J803 and APU starter contactor assembly connector (A48P1) as follows:
From To Expected Result Result J803-L A48P1-e <3 ohms - If the resistance check is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance check is as mentioned above, continue with next step.
- Perform a continuity check between connector J803 and FADEC tray connector (A108BP1) as follows:
From To Expected Result Result J803-E A108BP1-C4 <3 ohms J803-F A108BP1-D4 <3 ohms - If the resistance check is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance check is as mentioned above, continue with next step.
- Perform a continuity check between connector J803 and grounded shell as follows:
From To Expected Result Result J803-E Ground >1 megaohm J803-F Ground >1 megaohm - If the resistance check is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance check is as mentioned above, continue with next step.
- Replace Inlet Door Actuator.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace FADEC.
- Do close out.