09/24/19
Message Overview:
Fault Message:
INLET DOOR RTRY XDCR FAIL/POS ADJ
Fault Code:
4960322APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-60-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
During the rigging of the inlet door, the Full-Authority Digital Engine-Controller (FADEC) received signals from the Inlet-Door Rotary Transducer that are higher than they should be. This message does not show a failure condition. No fault isolation procedures are necessary.
Possible Causes:
- Inlet-Door Rotary Transducer (MT5)
- Full-Authority Digital Engine-Controller (FADEC) (A108)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None