Message Overview:
Fault Message:
TIME TOTALIZING METER [DATA XCHECK]
Fault Code:
4960326APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-70-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-12-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Hour Meter data stored by the Full Authority Digital Engine-Controller (FADEC) does not match the data transmitted by the Hour Meter to the FADEC.
Possible Causes:
- Time Totalizing Meter (M1)
- Auxiliary Power Unit (APU) Full Authority Digital Engine-Controller (FADEC) (A108)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Hours Meter indicated 0 or does not update.
Quick Links:
| Removal of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) |
AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Time Totalizing Meter | AMM 49-70-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Time Totalizing Meter | AMM 49-70-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Examine the Time Totalizing Meter (M1) receptacle for contamination and damage.
- If there is contamination or damage, go to step 5.
- If there is no contamination or damage, continue with next step.
- Check for insulation resistance between time totalizing meter connector (M1P1) and the shell as follows:
From To Expected Result Result M1P1-C Shell >1 Mohm - If the resistance values are not within range, go to step 5.
- If the resistance values are within range, continue with next step.
- Connect the hour meter/start counter reader to the time totalizing meter (M1). Push down and hold the push-button on the hour meter/start counter reader.
- If there is no data on the EVENTS LED, go to step 5.
- If there is data on the EVENTS LED, continue with next step.
- Perform wiring checks between FADEC connector (A108AP1) and Time Totalizing Meter connector (M1P1) as follow:
From To Result A108AP1-B1 M1P1-A A108AP1-A2 M1P1-B A108AP1-A1 M1P1-C - If the wiring checks are not good, repair defective wiring as required and do close out.
- If the wiring checks are good, continue with next step.
- Replace Time Totalizing Meter.
- If system checks out, do close out.
- If fault remains, continue with next step.
- Replace FADEC.
- Do close out.