09/26/19
Message Overview:
Fault Message:
R DATA ENTRY PLUG CH B
Fault Code:
7326529RBR
Associated CAS:
| Reporting LRU: | Right Engine Electronic Controller (EEC) |
| System Description: | 73-20-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
The Right Data Entry Plug (DEP) input to Engine Electronic Controller (EEC) channel B has been detected failed.
Possible Causes:
- Right Data Entry Plug (DEP)
- Right Engine Electronic Controller (EEC)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
CAUTION: THE DATA ENTRY PLUG MUST BE TRIMMED ACCORDING TO THE INFORMATION GIVEN ON THE DATA ENTRY PLUG COVER. CHANGES TO THE TRIM OF THE DATA ENTRY PLUG WILL CAUSE THE ENGINE TO GIVE INCORRECT THRUST VALUES. THIS MAY CAUSE DAMAGE TO THE ENGINE. IF YOU ARE NOT SURE, CONTACT ROLLS-ROYCE DEUTSCHLAND.
Quick Links:
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Trim the Data Entry Plug | AMM 73-21-02-820-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Eng Electronic Controller (EEC) Mod 73-101559 |
EMM 73-21-01-000-801-B00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Eng Electronic Controller (EEC) Mod 73-101559 |
EMM 73-21-01-400-801-B001 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Entry Plug | EMM 73-21-02-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Entry Plug | EMM 73-21-02-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the CAIMS PMAT, get access to system diagnostics (AMM TASK 45-45-00-970-804).
- Go to the pages for the DEP wiring for the affected engine.
- Make sure that on the applicable pages, the DEP trim values are the same as on the DEP cover.
- If the condition remains, go to step 5.
- If the condition is not present, continue with next step.
- Swap Right EEC with Left EEC.
- If system checks are good, replace Right EEC and do close out.
- If fault remains, continue with next step.
- Disconnect the DEP (EMM TASK 73-21-02-000-801) and remove the end cap of the DEP.
- Examine the configurations of the jumper leads in channels A and B and make sure they are the same and the jumper leads are correctly attached.
- If there is no same configuration for the jumper leads, replace as required and do close out.
- If there is same configuration for the jumper leads, continue with next step.
- Examine the EEC pins, DEP sockets and jumper leads to make sure there is no damage or corrosion.
- If there is a damage, repair as required and do close out.
- If there is no damage, continue with next step.
- Perform wiring checks of the DEP.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform the Trim of the Data Entry Plug EMM TASK 73-21-02-820-801.
NOTE: Make sure that the DEP trim procedure is checked by a qualified person. - Do close out.