09/27/19
Message Overview:
Fault Message:
L FMU CH A WRG/FMU[FMV LVDT] RNG
Fault Code:
7326616LBR
Associated CAS:
| Reporting LRU: | Left Engine Electronic Controller (EEC) |
| System Description: | 73-20-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | 71-50-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Engine Electronic Controller (EEC) senses that the signal from the Linear Variable Differential Transformer for channel A is out of range. The Fuel Metering Unit (FMU) circuits are continuously monitored by the Full-Authority Digital Engine-Controller (FADEC).
Possible Causes:
- Fuel Metering Unit (FMU)
- Left Engine Electronic Controller (EEC)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Opening of the Cowls | AMM 71-10-00-010-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of the Cowls | AMM 71-10-00-410-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Connection of Electrical Connectors | EMM 70-50-01-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Eng Electronic Controller (EEC) Mod 73-101559 |
EMM 73-21-01-000-801-B00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Eng Electronic Controller (EEC) Mod 73-10155 |
EMM 73-21-01-400-801-B001 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Fuel Metering Unit | EMM 73-21-03-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Fuel Metering Unit | EMM 73-21-03-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform a visual inspection of the interface wiring for damage between the EEC connector (P1044) and the FMU connector (P1049).
- If there is damage, repair defective wiring as required and do close out.
- If there is no damage, continue with next step.
- Perform wiring checks between the EEC and the FMU.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform a resistance check of the FMU as follows:
From To Resistance Value Result P1049-3 P1049-4 73 - 107 ohms at 50 °F (10 °C) ±1.75 ohms per 9 °F (5 °C) P1049-8 P1049-7 130 - 190 ohms at 50 °F (10 °C) ±3 ohms per 9 °F (5 °C) P1049-5 P1049-6 130 - 190 ohms at 50 °F (10 °C) ±3 ohms per 9 °F (5 °C) P1049-3 Ground >40 megohm P1049-8 Ground >40 megohm P1049-5 Ground >40 megohm - If the resistance is not within range, repair defective wiring as required and do close out.
- If the resistance is within range, continue with next step.
- Replace FMU.
- Do close out.