Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

09/27/19

Message Overview:

Fault Message:

R IOP CH A WRG/FMU[IOP SOL] RNG MA

Fault Code:

7326622RBR

Associated CAS:

None

Reporting LRU: Fuel Metering Unit (FMU)
System Description: 73-20-00
Schematic Diagram: None
Wiring Diagram: 71-50-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

This message shows when:

  • There is an error of resistance in the Combined Overspeed and Shut-off Solenoid (COSS) for channel A of the Fuel Metering Unit (FMU)
  • There is an open circuit or a short circuit in the interface wiring

Possible Causes:

  • Fuel Metering Unit (FMU)
  • Right Engine Electronic Control (EEC)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

Forum Articles/Infoservice/Newsletter: None

NOTE: Both Channel A and Channel B SAV solenoid circuits faults must be detected to set the R ENG SAV FAIL (Caution) CAS message.

Quick Links:

Opening of the Cowls AMM 71-10-00-010-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of the Cowls AMM 71-10-00-410-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Connection of Electrical Connectors EMM 70-50-01-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Eng Electronic Controller (EEC)
Mod 73-101559
EMM 73-21-01-000-801-B00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Eng Electronic Controller (EEC)
Mod 73-101559
EMM 73-21-01-400-801-B001 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Fuel Metering Unit EMM 73-21-03-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Fuel Metering Unit EMM 73-21-03-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Perform a visual inspection of the interface wiring for damage between the EEC connector (P1044) and the FMU connector (P1049).

    1. If there is damage, repair defective wiring as required and do close out.
    2. If there is no damage, continue with next step.

  2. Perform wiring checks between the EEC and the FMU.

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  3. Replace FMU.
  4. Do close out.