Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

10/10/19

Message Overview:

Fault Message:

L TR LOWER R LOCK SW/WRG/P LOCK

Fault Code:

7325722LBR

Associated CAS:

L REVERSER FAIL
(Caution)

L REV LOCK FAULT
(Advisory)

Reporting LRU: Left Engine Electronic Controller (EEC)
System Description: 78-30-00
Schematic Diagram: 78-34-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 71-50-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Left Engine Thrust Reverser (TR) Lower Door Right Stow Switch indicates that the door is not fully stowed when the TR is commanded stowed.

Possible Causes:

  • Door Stow Switch
  • Primary Lock Actuator
  • Left Engine Electronic Controller (EEC)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

  1. TR Stow switch is also called the TR retracted switch.

Rolls-Royce NTO:

  • NTO 066, Issue 4 - TRU Binding Primary Door Lock Mechanism
  • NTO 135, Issue 1 - Issue of repeat Technical Variance 11595R (TR Stow Switch)
  • Rolls-Royce SB-BR 700-78-101529

Quick Links:

Opening of the Cowls AMM 71-10-00-010-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of the Cowls AMM 71-10-00-410-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Thrust Reverser Safety Precautions AMM 78-30-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Deactivation of the Thrust Reverser (for Maintenance) AMM 78-30-00-040-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Activation of the Thrust Reverser (for Maintenance) AMM 78-30-00-440-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Visual Check of the Thrust Reverser System AMM 78-30-00-210-807 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Manual Opening of the Pivoting Doors AMM 78-31-01-010-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Manual Closing of the Pivoting Doors AMM 78-31-01-410-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Eng Electronic Controller (EEC)
Mod 73-101559
EMM 73-21-01-000-801-B00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Eng Electronic Controller (EEC)
Mod 73-101559
EMM 73-21-01-400-801-B001 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Exhaust Access Panels EMM 78-00-00-010-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Exhaust Access Panels EMM 78-00-00-410-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Rigging check of the Pivoting Doors EMM 78-31-01-220-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Rigging of the Pivoting Doors EMM 78-31-01-820-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Primary Lock Actuator and Mechanism EMM 78-33-04-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Primary Lock Actuator and Mechanism EMM 78-33-04-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Door Retracted Switch EMM 78-34-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Door Retracted Switch EMM 78-34-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Check door rigging, including distortion, debris or damage around the TR door.

    1. If system checks are good, do close out
    2. If fault remains, continue with next step

  2. Check primary lock actuator and mechanism for sign of corrosion or binding.

    1. If system checks are good, do close out
    2. If fault remains, continue with next step

  3. Perform a continuity check on door stow switch. Shall have continuity when TR door is closed.

    From To Result
    P7006-1 P7006-2
    P7010-1 P7010-2

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  4. Perform wiring checks between door stow switch and EEC.

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  5. Replace Left EEC.
  6. Do close out.