10/11/19
Message Overview:
Fault Message:
R SAV CH B SUPPLY FAILURE
Fault Code:
7327315RBR
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 80-11-00 |
| Schematic Diagram: | 80-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 71-50-01 [ Global Express ] [ G5000 ] [ Global XRS ] 80-11-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
There is an electrical fault in the power supply to channel B of the Starter Air Valve (SAV). The power supply to the SAV is monitored by the Full-Authority Digital Engine-Controller (FADEC) during engine start.
Possible Causes:
- Right Engine Electronic Controller (EEC)
- Full-Authority Digital Engine-Controller (FADEC) (A108)
- Starter Air Valve (SAV)
- Secondary Power Distribution Assembly (SPDA) 1 (A13)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Opening of the Cowls | AMM 71-10-00-010-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of the Cowls | AMM 71-10-00-410-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Eng Electronic Controller (EEC) Mod 73-101559 |
EMM 73-21-01-000-801-B00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Eng Electronic Controller (EEC) Mod 73-101559 |
EMM 73-21-01-400-801-B001 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between SPDA 1 and the Right EEC.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Swap SPDA 1 with SPDA 3.
- If system checks are good, replace SPDA 1 and do close out.
- If fault remains, continue with next step.
- Replace Right EEC.
- Do close out.