Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/22/21

Message Overview:

Message Name:

INERTIAL REFERENCE SYSTEM (IRS) COOLING FANS

Identifier: 215OBS008
Effectivity: All
System: Avionics Cooling System
Associated CAS: None
System Description: 21-54-00
Schematic Diagram: 21-54-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]
21-54-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
34-45-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

The EICAS display shows IRS 1-2-3 OVHT and/or one or more IRS cooling fans do not operate.

Possible Causes:

  • Inertial Reference System Cooling Fans
  • Secondary-Power Distribution Assembly (SPDA) 3 (A15)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Notice To Operators (NTO): None

Flight Operation Notifications Manual (FONM): None

Quick Links:

Operational Test of the Inertial Reference System (IRS) Cooling Fans AMM 21-54-01-710-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Inertial Reference System (IRS) Cooling Fans AMM 21-54-01-000-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Inertial Reference System (IRS) Cooling Fans AMM 21-54-01-400-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Connect Electrical Power to the Aircraft AMM 24-00-00-861-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Opening of Non-Thermal Circuit Breakers AMM 24-00-00-863-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of Non-Thermal Circuit Breakers AMM 24-00-00-863-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Secondary-Power Distribution Assemblies AMM 24-62-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Secondary-Power Distribution Assemblies AMM 24-62-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Operational Test of the Secondary-Power Distribution Assembly 3 AMM 24-62-01-710-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the External Avionics-Compartment Access-Panel AMM 52-45-11-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the External Avionics-Compartment Access-Panel AMM 52-45-11-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions-Maintenance Practices SPM 20-00-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Disconnect affected IRS cooling fan input power wires. Perform a 28 VDC voltage check as follows:
    For the IRS fan 1 (B31):

    From To Expected Result Result
    +28 VDC IRU 1 FAN PWR Ground 28 VDC
    +28 VDC IRU 1 FAN RTN Ground Continuity

    For the IRS fan 2 (B36):

    From To Expected Result Result
    +28 VDC IRU 2 FAN PWR Ground 28 VDC
    +28 VDC IRU 2 FAN RTN Ground Continuity

    For the IRS fan 3 (B39):

    From To Expected Result Result
    +28 VDC IRU 3 FAN PWR Ground 28 VDC
    +28 VDC IRU 3 FAN RTN Ground Continuity

    1. If there is 28 VDC input at the fan and the ground is good, replace the IRS cooling fan.
    2. If voltage or grounding is missing, continue with next step.

  2. Disconnect associated SPDA 3 connector (A15P2, A15P3 or A15P4). Perform a continuity check as follows:
    For the IRS fan 1 (B31):

    From To Result
    +28 VDC IRU 1 FAN PWR A15P3-E

    For the IRS fan 2 (B36):

    From To Result
    +28 VDC IRU 2 FAN PWR A15P3-D

    For the IRS fan 3 (B39):

    From To Result
    +28 VDC IRU 3 FAN PWR A15P3-G

    1. If there is continuity, troubleshoot the SPDA 3 power source.
    2. If there is no continuity, repair defective wiring as required.

  3. Do close out.