06/22/21
Message Overview:
Message Name:
THE PACK INLET TEMPERATURE SENSOR INDICATION ON THE PMAT IS OUT OF TOLERANCE COMPARED WITH AMBIENT TEMPERATURE
| Identifier: | 215OBS012 |
| Effectivity: | All |
| System: | AIR CONDITIONING |
| ASSOCIATED CAS: | None |
| System Description: | 21-51-00 |
| Schematic Diagram: | 21-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | None |
Message Description:
ACSC receives an incorrect temperature signal from a pack inlet temperature sensor.
Possible Causes:
- Left pack inlet temperature sensor E23
- Right pack inlet temperature sensor E29
- Interface wiring between left pack inlet temperature sensor and Air-Conditioning System Controller (ACSC) 1
- Interface wiring between right pack inlet temperature sensor and Air-Conditioning System Controller (ACSC) 2
- Air-Conditioning System Controller (ACSC) 1
- Air-Conditioning System Controller (ACSC) 2
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Troubleshooting Recommendations:
- Perform the following CAIMS troubleshooting:
- [ACSC1-A] LH PCK IN TEMP SENS /WRG (2161425ECS)
- [ACSC1-B] LH PCK IN TEMP SENS /WRG (2162425ECS)
- [ACSC2-A] RH PCK IN TEMP SENS /WRG (2163425ECS)
- [ACSC2-B] RH PCK IN TEMP SENS /WRG (2164425ECS)
- Do close out.