Message Overview:
Message Name:
RADIO FREQUENCY UNIT (RFU) COOLING FAN INOPERATIVE
| Identifier: | 215OBS014 |
| Effectivity: | AC9002 to AC9135 only |
| System: | Air Conditioning System |
| Associated CAS: | None |
| System Description: | 21-54-00 |
| Schematic Diagram: | 21-54-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
RFU fan does not operate.
Possible Causes:
- RFU Fan has an obstruction and cannot turn freely
- Fan
- Fan Wiring
- Radio Frequency Unit (RFU)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| RFU Cooling Fan - Removal | AMM 21-54-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| RFU Cooling Fan Cooling Fans - Installation | AMM 21-54-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check for 115 VAC power supplied to RFU fan at A35J2 pin H. (Make sure circuit breaker SATCOM FREQ UNIT is closed).
- If no 115 VAC, continue with next step.
- If there is 115 VAC, go to step 3.
- Repair wiring of CPB1.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring checks between RFU fan, RFU and CBP1.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace defective RFU fan.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace RFU.
- Do close out.