Message Overview:
Message Name:
SATELLITE DATA UNIT COOLING FAN INOPERATIVE
| Identifier: | 215OBS015 |
| Effectivity: | AC9002 to AC9135 only |
| System: | Air Conditioning |
| Associated CAS: | None |
| System Description: | 21-54-00 |
| Schematic Diagram: | 21-54-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
SDU fan does not operate.
Possible Causes:
- Satellite Data Unit (SDU) Fan has an obstruction and cannot turn freely
- Secondary Power Distribution Assembly (SPDA) 4
- Satellite Data Unit (SDU) Fan
- Fan Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| SDU Cooling Fan - Removal | AMM 21-54-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| SDU Cooling Fan Cooling Fans - Installation | AMM 21-54-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Secondary Power Distribution Assemblies - Removal | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Secondary Power Distribution Assemblies - Installation | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check for 28 VDC power supplied to SDU fan at SPDA4 A16P1 pin m.
- If no 28 VDC, continue with next step.
- If there is 28 VDC, go to step 3.
- Interchange SPDA4.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring checks between SDU fan and SPDA4.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace defective SDU fan.
- Do close out.