06/22/21
Message Overview:
Message Name:
UNSATISFACTORY FRESH AIRFLOW INTO THE FLIGHT AND PASSENGER COMPARTMENTS
| Message Code: | 215OBS020 |
| Effectivity: | All |
| System: | Air Conditioning System |
| Associated CAS: | None |
| System Description: | 21-52-00 |
| Schematic Diagram: | 21-52-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-52-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The possible cause is high air leakage related to the mix manifold.
Possible Causes:
- Mix Manifold
- Mix Manifold Connections
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Leak Test of the Internal Distribution System | AMM 21-21-00-790-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Do the leak test of the internal distribution system. With leak detector bleed-air, do a check for leakage at the mix manifold and related connections.
- Repair connections that have leakage.
- Remove and replace the defective components.
- Do close out.