Message Overview:
Message Name
CABIN COMMUNICATION SYSTEM INOP
| Message Code: | 231OBS001 |
| Effectivity: | Global Express, Global XRS |
| System: | HF Communication |
| System Description: | 23-14-00 |
| Schematic Diagram: | 23-14-00 [ Global Express ] [ Global XRS ] |
| Wiring Diagram: | 23-14-01 [ Global Express ] [ Global XRS ] |
Message Description:
The cabin communication system is unserviceable.
Possible Causes:
- Air Radio-Telecommunication Unit (ARTU) (A246)
- Cabin Distribution Bus Repeater (CDBR) (A243)
- Cabin Distribution Bus Repeater (CDBR) (A244)
- Cabin Distribution Bus Repeater (CDBR) (A245)
- Cabin Handset
- Duplexer (A247)
- Call Alerter switch
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-23-0646 - Rockwell Collins Handsets Obsolescence
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Air Radio−Telecommunications Unit (ARTU) | AMM 23-14-01-000-801 [ Global Express ] [ Global XRS ] |
| Installation of the Air Radio−Telecommunications Unit (ARTU) | AMM 23-14-01-400-801 [ Global Express ] [ Global XRS ] |
| Removal of the Cabin Distribution−Bus Repeaters | AMM 23-14-13-000-801 [ Global Express ] [ Global XRS ] |
| Installation of the Cabin Distribution−Bus Repeaters | AMM 23-14-13-400-801 [ Global Express ] [ Global XRS ] |
| Removal of the Duplexer | AMM 23-14-17-000-801 [ Global Express ] [ Global XRS ] |
| Installation of the Duplexer | AMM 23-14-17-400-801 [ Global Express ] [ Global XRS ] |
| Removal of the Call Alerter Switch | AMM 23-14-21-000-801 [ Global Express ] [ Global XRS ] |
| Installation of the Call Alerter Switch | AMM 23-14-21-400-801 [ Global Express ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access the ARTU. On the face of the unit, is the green LED on?
- If YES, go to step 6.
- If NO, continue with next step.
- On the EMS CDU open the AIRPHONE SYSTEM circuit breaker and remove the ARTU.
- On the EMS CDU close the AIRPHONE SYSTEM circuit breaker. Perform a 28 VDC voltage check and ground check as follows:
From To Expected Result Result A246AP2-A Ground 28 VDC A246AP2-B Ground 28 VDC A246AP2-C Ground Continuity - If voltage and ground are good, continue with next step.
- If voltage and ground are not good, investigate wiring and/or power source and repair as required.
- Perform a continuity check as follows:
From To Result A246AP1-5 A246P2-D A246AP1-6 A246P2-E A246AP1-1 A246P2-C A246AP1-3 A246P2-A A246AP1-4 A246P2-B A246AP1-g A246P2-F - If there is continuity, continue with next step.
- If there is no continuity, repair defective wiring as required.
- Perform a continuity check as follows:
From To Result A246AP1-5 Ground A246AP1-6 Ground A246AP1-1 Ground A246AP1-3 Ground A246AP1-4 Ground A246AP1-9 Ground - If there is continuity, repair defective wiring as required.
- If there is no continuity, continue with next step.
- On the face of the unit, is the red LED on?
- If YES, replace the ARTU.
- If NO, continue with next step.
- On the face of the unit, are the red and green LED on?
- If YES, replace the ARTU.
- If NO, continue with next step.
- On the face of the unit, does the green LED come on for less than one second and then go off?
- If YES, continue with next step.
- If NO, go to step 14.
- On the EMS CDU open the AIRPHONE SYSTEM circuit breaker. Disconnect ARTU connector A246P1.
- On the EMS CDU close the AIRPHONE SYSTEM circuit breaker. Does the green LED come on and stay on steady?
- If YES, continue with next step.
- If NO, go to step 14.
- On the EMS CDU, open the following circuit breakers: AIRPHONE SYSTEM and AIRPHONE REPEATER. Disconnect CDBR 1 connector A243P1. Perform a continuity check as follows:
From To Result A246P1-M Ground A246P1-N Ground A246P1-d Ground A246P1-P Ground A246P1-J Ground A246P1-K Ground A246P1-L Ground A246P1-b Ground A246P1-X Ground A246P1-Y Ground A246P1-E Ground A246P1-F Ground - If there is continuity, repair defective wiring as required.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A246P1-M A243P1-1 A246P1-N A243P1-2 A246P1-d A243P1-3 A246P1-P A243P1-4 A246P1-J A243P1-7 A246P1-K A243P1-8 A246P1-L A243P1-10 A246P1-b A243P1-11 A246P1-X A243P1-12 A246P1-Y A243P1-13 A246P1-E A243P1-6 A246P1-F A243P1-9 - If there is continuity, continue with next step.
- If there is no continuity, repair defective wiring as required.
- Swap CDBR 1 with CDBR 2. Is the fault still present?
- If YES, continue with next step.
- If NO, replace defective CDBR.
- Replace the ARTU.
- Do close out.