06/22/21
Message Overview:
Message Name:
ACARS DMU FAIL ON FMS CDU
| Message Code: | 232OBS001 |
| Effectivity: | All |
| System: | Airborne Data Link System |
| System Description: | 23-23-00 |
| Schematic Diagram: | 23-23-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-23-01 [ Global Express ] [ G5000 ] [ Global XRS ] 23-23-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The ACARS DMU FAIL message shows on the Flight Management System Control Display Unit (FMS CDU) when the Integrated Avionics Computer (IAC)/FMS does not receive the correct health status from Airborne Data Link Unit (ADLU) on the ARINC 429 bus.
Possible Causes:
- Airborne Data Link Unit (ADLU) (A239)
- Secondary Power Distribution Assembly (SPDA) 4 (A16)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-23-0372 - No Fault Found initiative: Datalink
- AW700-23-0578 - FMS CDU ‘ACARS DMU FAILED’ message observed post Batch 3.3
- AW700-31-0563 - Batch 3.3 Software Upgrade - In-Service Observations
- AW700-31-0647 - Batch 3.4 Software Upgrade - Availability and Update
- AW700T-0123 - "ACARS DMU FAIL" Message
Forum Articles/Infoservice/Newsletter: None
NOTE 1: If the A/C has implemented the IAC Batch 3.3 software and is now experiencing an intermittent ACARS DMU FAIL Message on the FMS CDU, please make sure to review the content of AW700-31-0563 and fill out the questionnaire before attempting any troubleshooting.
NOTE 2: Resetting the DATALINK circuit breaker via the EMS CDU (Electrical Management System Control Display Unit) may clear the active fault.
Quick Links:
| Operational Test of the Data Link System | AMM 23-23-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Airborne Data-Link Unit | AMM 23-23-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Airborne Data-Link Unit | AMM 23-23-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Reset the DATALINK circuit breaker via the EMS CDU.
- Does the message ACARS DMU FAIL continues to show on the FMS CDU?
- If YES, go to step 5.
- If NO, continue with next step.D
- On the CAIMS PMAT find and record the related active/stored faults. Check faults listed under ATA 23-20 AIRBORNE DATA LINK UNIT. Refer to AMM 45-45-00-970-802. Did you record any fault messages in CAIMS (Active or Stored)?
- If YES, go to the applicable troubleshooting by CAIMS fault codes and do close out.
- If NO, continue with next step.
- Perform the operational test of the Airborne Data Link System (Refer to AMM 23-23-00-710-801) and do close out. Monitor ADLS within next few flights.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform a power check for the airborne data-link unit (ADLU). On the connector A239CP1, check if there is +28 VDC as follows:
From To Expected Result Result A239CP1-2 A239CP1-4 28 VDC - If there is +28 VDC, go to step 7.
- If there is no +28 VDC, continue with next step.
- Repair or replace the defective wiring between the ADLU and the SPDA 4. Is the fault still present?
- If NO, perform the fault isolation for the SPDA 4 and do close out.
- If YES, continue with next step.
- Perform a wiring check between the ADLU and the FMS CDUs and between the ADLU and the IACs (FMS). Refer to wiring diagram manual WM 23-23-00. Is the wiring checks satisfactory?
- If YES, go to step 9.
- If NO, repair or replace the defective wiring as required and continue with next step.
- Perform the operational test of the Airborne Data Link System (Refer to AMM 23-23-00-710-801).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the Airborne DATALINK Unit (ADLU).
- Do close out. Monitor ADLS within next few flights.