Message Overview:
Message Name:
AC/DC CABIN BUSS NOT POWERED AFTER EMS CDU REPLACEMENT
| Message Code: | 240OBS001 |
| Effectivity: | All |
| System: | |
| System Description: | 24-00-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | 24-00-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The AC cabin BUS and/or DC cabin Bus not powered after EMS CDU or SPDA replacement or a Virgin Start.
Possible Causes:
- AC and DC Cabin BUS Isolation Control are not ON
- AC and DC Cabin Switches Control are not IN
- AC and DC Cabin Feeders are not IN
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter:
NOTE: If AC cabin BUS and/or DC cabin Bus are found not powered without maintenance action performed, please refer to SFP OBS fault - CABIN SYSTEMS UNPOWERED AT AIRCRAFT POWER UP
If the AC and DC cabin power are not available after an EMS CDU, SPDA replacement or after a virgin start, verify:
- On EMS CDU, select BUS EMER CONT. On page 1/2 and 2/2, make sure AC and DC cabin power BUS isolation controls are ON.
- On EMS CDU, select SYS CNTL key. On page 2/3 and 3/3, make sure all AC and DC cabin power switches control are IN.
Quick Links:
None
Troubleshooting Recommendations:
- Make sure AC and DC cabin power BUS isolation control are IN on EMS CDU.
- If one or more are found "OUT", set them to "IN" and do close out
- If they are all "IN" continue with next step
- Make sure all AC and DC cabin power switches control are IN on EMS CDU.
- Do close out.