06/22/21
Message Overview:
Message Name:
CABIN SYSTEMS UNPOWERED AT AIRCRAFT POWER UP
| Message Code: | 247OBS002 |
| Effectivity: | All |
| System: | Electrical Power |
| System Description: | 24-70-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
Upon Aircraft power up, some cabin systems may be unpowered.
Possible Causes:
- Electrical Management System Control Display Unit (EMS CDU) 1 (A94)
- Electrical Management System Control Display Unit (EMS CDU) 2 (A91)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter:
- 20170418_ForumNewsletter - 2017-04-18 - Cabin power missing
Quick Links:
| Access of Signboard Menu in EMS CDU | AMM 24-00-00-946-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Exit of Signboard Menu in EMS CDU | AMM 24-00-00-946-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the EMS CDU, select EMER CNTL and look at AC and DC CABIN PWR. Record if it is set to "ON" or "OFF".
- Select CNTL page 2 and 3 and look at the AC and DC CABIN POWER feeder status and record.
- Do not set any of them to "IN" before continuing with next steps.
- Download the DCPC and EMS CDU's NVM.
- Access the EMS CDU Signboard menu. Select DCPC IN.
- Select and record label 014 (DC Cabin Feed) bits 14 to 29.
Left Column Right column 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 Label 014 - On both EMSCDU access the Signboard menu. Select the "SYSTEM" key and make a selection of CDU Info and afterwards, DCPC Info. Record the Active Microprocessor. Perform two aircraft power up, recording the Cabin power status (steps 1 and 2) and the active Microprocessor every time.
Result First Power up Second Power up CDU INFO Active Microprocessor DCPC INFO Active Microprocessor - Using the EMS CDU set all of the Cabin Power to "ON" (steps 1 and 2) and confirm that cabin systems are now working. Repeat step 7 and record values.
Result First Power up Second Power up CDU INFO Active Microprocessor DCPC INFO Active Microprocessor - Remove power from the aircraft, access the DCPC logic assembly and replace the defective DCPC Microprocessor cards. Repeat step 7 and record values.
Result First Power up Second Power up CDU INFO Active Microprocessor DCPC INFO Active Microprocessor - Send the results to the Bombardier Customer Response Center (CRC).
- Do close out.