Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/29/21

Message Overview:

Message Name:

FLIGHT CREW FLOOR-HEATERS UNSERVICEABLE

Message Code: 251OBS002
Effectivity: All
System: Heated Floor Mats
System Description: 25-13-00
Schematic Diagram: 25-13-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 25-13-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

The Floor Heater does not operate. The result is that the air temperature is colder at the Flight Crew Floor.

Possible Causes:

  • Heated Floor Mat
  • Copilot Floor Heater 1 (HR2)
  • Copilot Floor Heater 2 (HR3)
  • Pilot Floor Heater 1 (HR4)
  • Pilot Floor Heater 2 (HR5)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Notice To Operators (NTO): None

Flight Operation Notifications Manual (FONM): None

Quick Links:

Opening of Non-Thermal Circuit Breakers AMM 24-00-00-863-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of Non-Thermal Circuit Breakers AMM 24-00-00-863-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Flight Crew Floor-Heaters AMM 25-13-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Flight Crew Floor-Heaters AMM 25-13-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Flight Compartment Floor-Panels AMM 53-11-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Flight Compartment Floor-Panels AMM 53-11-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Standard Practices - System Description SPM 20-00-00-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Perform a continuity check of the wiring between the SPDA 1 and the heaters.

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.D

  2. Disconnect the connectors. Perform a continuity check as follows:
    For Pilot Heater 1:

    From To Result
    HR4J1-A A13P2-H
    HR4J1-B GS306

    For Pilot Heater 2:

    From To Result
    HR5J1-A A13P2-H
    HR5J1-B GS306

    For Copilot Heater 1:

    From To Result
    HR2J1-A A13P3-H
    HR2J1-B GS305

    For Copilot Heater 2:

    From To Result
    HR3J1-A A13P3-H
    HR3J1-B GS305

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  3. Replace the defective floor heater. Connect the disconnected connectors.
  4. Do close out.