Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/29/21

Message Overview:

Message Name:

FAIL INDICATION ON THE REFUEL/DEFUEL CONTROL PANEL

Message Code: 282OBS001
Effectivity: All
System: Refuel/Defuel System
System Description: 28-23-00
Schematic Diagram: 28-23-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 28-23-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

Fail shows on the Refuel/Defuel Control Panel during Refuel/Defuel procedures. The Fuel Management and Quantity Gauging Computer (FMQGC) senses an internal failure or the RDCP is defective.

Possible Causes:

  • Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
  • Refuel/Defuel Control Panel (RDCP) (A46)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Connect Electrical Power to the Aircraft AMM 24-00-00-861-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the REFUEL/DEFUEL
Control Panel
AMM 28-23-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the REFUEL/DEFUEL
Control Panel
AMM 28-23-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Computer AMM 28-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Computer AMM 28-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Self-Test of the Computer AMM 28-41-01-740-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Flight Deck Effect to Fault Correlations AMM 45-45-00-970-821 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Check if one of the following fault messages appears on the CAIMS PMAT.

    1. If YES, perform the applicable troubleshooting and do close out.
    2. If NO, continue with the next step.

  2. Check if the indications that follow show on the REFUEL/DEFUEL Control Panel.

    Reference Indication
    PRESEL FAIL
    RIGHT Dashes
    AFT Dashes
    TOTAL TOTAL Value
    LEFT PRESEL Value
    CTR LEFT/RIGHT/CTR/AFT Values (One at a time)

    1. If YES, go to step 6.
    2. If NO, continue with the next step.

  3. Check if the indications that follow show on the REFUEL/DEFUEL Control Panel.

    Reference Indication
    PRESEL FAIL
    RIGHT RIGHT Value
    AFT AFT Value
    TOTAL TOTAL Value
    LEFT LEFT Value
    CTR CTR Value

    1. If NO, perform the troubleshooting for Obseved Fault "SOV FAIL indication on the REFUEL/DEFUEL control panel" and do close out.
    2. If YES, replace the FMQGC and continue with next step.

  4. Perform a self-test of the fuel computer.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  5. Check if FAIL is shown on the REFUEL/DEFUEL Control Panel.

    1. If NO, do close out.
    2. If YES, continue with next step.

  6. Replace Refuel/Defuel Control Panel.
  7. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.