06/29/21
Message Overview:
Message Name:
SOV FAIL INDICATION ON THE REFUEL/DEFUEL CONTROL PANEL
| Message Code: | 282OBS005 |
| Effectivity: | All |
| System: | Refuel/Defuel System |
| System Description: | 28-23-00 |
| Schematic Diagram: | 28-23-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-23-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
SOV FAIL shows on the Refuel/Defuel Control Panel when one of the Refuel Manifold Control Valves fails during refuel procedures.
Possible Causes:
- Aft Refuel Shutoff Valve (L4)
- Aft Refuel Shutoff Valve-Actuator
- Left Manifold Control Valve (L5)
- Right Manifold Control Valve (L6)
- Center Manifold Control Valve (L7)
- Junction Box (JB6)
- Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Pressure Refueling | AMM 12-11-01-650-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Manifold Control Valves | AMM 28-23-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Manifold Control Valves | AMM 28-23-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Aft Refuel Shutoff-Valve-Actuator | AMM 28-23-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Aft Refuel Shutoff-Valve-Actuator | AMM 28-23-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Flight Deck Effect to Fault Correlations | AMM 45-45-00-970-821 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access CAIMS Active or stored Faults. Select displayed message from menu below:
- If any associated CAIMS message is displayed, troubleshoot them first and continue with next step.
- If no associated CAIMS message is displayed, continue with next step.
- Check FAIL shows for the AFT tank quantity on the RDCP.
- If FAIL shows for the AFT tank quantity on the RDCP, replace the aft refuel shutoff-valve-actuator and do close out.
- If FAIL does not show for the AFT tank quantity on the RDCP, continue with the next step.
- Check FAIL shows for the Left, Right or CTR tank quantity on the RDCP.
- If FAIL does not show for the Left, Right or CTR tank quantity on the RDCP, do close out.
- If FAIL shows for the Left, Right or CTR tank quantity on the RDCP, continue with the next step.
- Replace defective Manifold Control Valve.
- Do close out.