Message Overview:
Message Name:
FUEL QUANTITY DOES NOT SHOW OR SHOWS DASHES ON REFUEL/DEFUEL CONTROL PANEL
| Message Code: | 284OBS003 |
| Effectivity: | All |
| System: | Fuel Management and Quantity Gauging System |
| System Description: | 28-41-00 |
| Schematic Diagram: | 28-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-41-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The fuel quantity is blank or dashed on the REFUEL/DEFUEL Control Panel (RDCP) or the Engine Indication and Crew Alerting System (EICAS) display. If the quantity gauging does not operate for one Fuel Tank, the quantity of Fuel in that Tank and the total quantity show dashes on the RDCP. If the fuel quantity gauging system does not operate, all quantities on the RDCP show dashes.
Possible Causes:
- Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
- Refuel/Defuel Control Panel (RDCP) (A46)
- Left Densitometer (A163)
- Center Tank Fuel Quantity Probe (C27)
- Center Tank Fuel Quantity Probe (C29)
- Left Wing Fuel Tank Compensator (C7)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter:
- Fuel tank gauging troubleshooting document
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the REFUEL/DEFUEL Control Panel | AMM 28-23-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the REFUEL/DEFUEL Control Panel | AMM 28-23-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Densitometer | AMM 28-41-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Densitometer | AMM 28-41-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Compensator | AMM 28-41-29-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Compensator | AMM 28-41-29-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Flight Deck Effect to Fault Correlations | AMM 45-45-00-970-821 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check if one of the fault messages that follow appears on the CAIMS PMAT.
- If YES, perform the applicable troubleshooting and continue with next step.
- If NO, replace the FMQGC and continue with next step.
- Check if the fuel quantity show as blank or dashed on the RDCP.
- If NO, do close out.
- If YES, continue with next step.
- Replace the RDCP.
- Do close out.