06/29/21
Message Overview:
Message Name:
HYD 1 PRESSURE INDICATION
| Message Code: | 293OBS001 |
| Effectivity: | All |
| System: | Engine Indicating |
| System Description: | 29-30-00 |
| Schematic Diagram: | 29-12-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 29-00-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Data Acquisition Unit (DAU) 1 is reporting Hydraulic System 1 pressure incorrectly, erratically or dashed.
Possible Causes:
- Data Acquisition Unit (DAU) 1 (A17)
- Hydraulic System 1 Pressure Transducer (MT140)
- Secondary Power Distribution Assembly (SPDA) 3 (A15)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies |
AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies |
AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Hydraulic Pressure Transducers | AMM 29-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Hydraulic Pressure Transducers | AMM 29-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap Hydraulic System 1 Pressure Transducer with Hydraulic System 2 Pressure Transducer.
- If system checks are good, replace Hydraulic System 1 Pressure Transducer and do close out.
- If fault remains, continue with next step.
- Swap DAU 1 with DAU 2.
- If system checks are good, replace DAU 1 and do close out.
- If fault remains, continue with next step.
- Perform wiring check between DAU 1, Hydraulic Pressure Transducer 1 (MT140), and SPDA 3.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform a voltage check as follows:
Hydraulic System 1
Pressure TransducerExpected Result MT140P1-D 28 VDC - If there is 28 VDC, do close out.
- If there is no 28 VDC, continue with next step.
- Replace SPDA 3.
- Do close out.