06/29/21
Message Overview:
Message Name:
HYD 2 PRESSURE INDICATION
| Message Code: | 293OBS004 |
| Effectivity: | All |
| System: | Engine Indicating |
| System Description: | 29-30-00 |
| Schematic Diagram: | 29-12-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 29-00-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Data Acquisition Unit (DAU) 2 is reporting Hydraulic System 2 pressure incorrectly, erratically or dashed.
Possible Causes:
- Data Acquisition Unit (DAU) 2 (A18)
- Hydraulic System 2 Pressure Transducer (MT143)
- Secondary Power Distribution Assembly (SPDA) 2 (A14)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies |
AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies |
AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Hydraulic Pressure Transducers | AMM 29-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Hydraulic Pressure Transducers | AMM 29-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap Hydraulic System 2 Pressure Transducer (MT143) with Hydraulic System 1 Pressure Transducer (MT140).
- If system checks are good, replace Hydraulic System 2 Pressure Transducer and do close out.
- If fault remains, continue with next step.
- Swap DAU 2 with DAU 1.
- If system checks are good, replace DAU 2 and do close out.
- If fault remains, continue with next step.
- Perform wiring check between DAU 2, Hydraulic Pressure Transducer 2 (MT143), and SPDA 2.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform voltage check as follows:
Hydraulic System 2
Pressure TransducerExpected Result MT143P1-D 28 VDC - If there is 28 VDC, do close out.
- If there is no 28 VDC, continue with next step.
- Replace SPDA 2.
- Do close out.